FireCADCalc

Oxygen Uptake, CO₂ Evolution and Respiratory Quotient from Off-Gas

Oxygen uptake rate, carbon dioxide evolution rate and respiratory quotient of a fermenter from air flow and dry inlet and exhaust O₂ and CO₂ by nitrogen balance.

Distillery and ethanolChemical and fertiliserFood, dairy and textile

Inputs

Examples: Illustrative 10 m3 fermenter, 500 Nm3/h airYeast overflow, RQ above 1Oxygen-enriched inlet

Accepted: 0.0036 to 360,000 Nm³/h
Accepted: 15 to 40 %
Accepted: 0 to 5 %
Accepted: 5 to 40 %
Accepted: 0 to 20 %
Accepted: 0.0001 to 10,000 m³

Results

Inert (N₂ + Ar) balance: V_out = V_in(1 − y_O₂,in − y_CO₂,in)/(1 − y_O₂,out − y_CO₂,out); OUR and CER from the O₂ and CO₂ balances at 22.414 L/mol. RQ ≈ 1 on glucose growth, 0.7 on fats, above 1 when ethanol or other reduced products form (overflow metabolism). The last output is the uptake per litre of broth per hour.

Exhaust flow (dry, normal)99.658Nm³/h
Oxygen uptake rate0.13796kmol/h
CO₂ evolution rate0.12271kmol/h
Respiratory quotient0.88944
Oxygen uptake per litre of broth per hour68.982mmol/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m3 fermenter, 500 Nm3/h air. The inputs, in the units selected above:

InputValue
Inlet air flow (dry, normal)500.00 Nm³/h
Inlet O₂ (dry)20.950 %
Inlet CO₂ (dry)0.040000 %
Exhaust O₂ (dry)19.500 %
Exhaust CO₂ (dry)1.2000 %
Broth volume10.000 m³

Applying the formula below gives:

ResultValue
Exhaust flow (dry, normal)498.17 Nm³/h
Oxygen uptake rate0.33937 kmol/h
CO₂ evolution rate0.25779 kmol/h
Respiratory quotient0.75962
Oxygen uptake per litre of broth per hour33.937 mmol/L

Open this example in the calculator and change any input.

Formula

\(\dot V_{out} = \dot V_{in}\frac{1 - y_{O_2,in} - y_{CO_2,in}}{1 - y_{O_2,out} - y_{CO_2,out}}, \quad RQ = \frac{\dot V_{out}y_{CO_2,out} - \dot V_{in}y_{CO_2,in}}{\dot V_{in}y_{O_2,in} - \dot V_{out}y_{O_2,out}}\)

Variables

Symbol Meaning SI unit
\(\dot V_{in}\) Inlet air flow (dry, normal) Nm³/s
\(y_{O_2,in}\) Inlet O₂ (dry) -
\(y_{CO_2,in}\) Inlet CO₂ (dry) -
\(y_{O_2,out}\) Exhaust O₂ (dry) -
\(y_{CO_2,out}\) Exhaust CO₂ (dry) -
\(V_L\) Broth volume m³
\(\dot V_{out}\) Exhaust flow (dry, normal) Nm³/s
\(OUR\) Oxygen uptake rate mol/s
\(CER\) CO₂ evolution rate mol/s
\(RQ\) Respiratory quotient -
\(OUR/V_L\) Oxygen uptake per litre of broth per hour mol/m³

Method and standards

Off-gas balance.

Where it is used

  • Fermentation monitoring and control.
  • Detecting overflow metabolism in fed-batch.

Common mistakes

  • Using wet-gas readings.
  • Ignoring CO₂ dissolved in the broth at high pH.

Assumptions and limits

  • Steady state; inert gas unchanged; dry analysis.

References

  • Inert-gas balance off-gas analysis

Questions and answers

Why use a nitrogen balance?

Exhaust flow is rarely measured; nitrogen and argon pass unchanged, so their balance gives it from the gas analysis.

Why must the gases be dry?

Analysers read dry gas; humidity changes between inlet and exhaust would otherwise distort the fractions.

What do the defaults represent?

An illustrative 10 m³ fermenter aerated with 500 Nm³/h of air, exhaust at 19.5 % O₂ and 1.2 % CO₂ dry.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Doran, Bioprocess Engineering Principles, 2nd ed. (Academic Press, 2013)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.