FireCADCalc

Turbine Rotor Surface Thermal Stress during Start-Up

Surface-to-mean temperature difference and thermal stress in a turbine rotor heated at a steady rate, and the largest heating rate for an allowable stress.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 400 mm rotor at 3 K/minIP rotor 500 mm at 2 K/minSmall industrial rotor 200 mm at 8 K/min

Accepted: 50 to 1,000 mm
Accepted: 0 to 12 K/min
Accepted: 10 to 60 W/(m·K)
Accepted: 7,000 to 8,500 kg/m³
Accepted: 0.4 to 0.8 kJ/(kg·K)
Accepted: 100 to 250 GPa
Accepted: 5E-6 to 2E-5 1/K
Accepted: 0.2 to 0.4
Accepted: 1 to 5
Accepted: 50 to 1,000 MPa

Results

Quasi-steady heating of a solid cylinder at rate Ṫ: the profile is parabolic and the surface leads the mean by ṪR²/(8a); the surface stress is K_tEαΔT/(1 − ν) (compressive while heating, tensile on cooling). Start-up curves limit heating rates so that low-cycle fatigue life is respected; bored rotors and thick casings need their own geometry factors.

Thermal diffusivity8.5742mm²/s
Surface minus mean temperature77.752K
Peak surface thermal stress487.34MPa
Largest heating rate for the allowable4.9247K/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 mm rotor at 3 K/min. The inputs, in the units selected above:

InputValue
Rotor radius (solid) at the section400.00 mm
Steam/surface heating rate3.0000 K/min
Rotor steel conductivity30.000 W/(m·K)
Density7,800.0 kg/m³
Specific heat0.56000 kJ/(kg·K)
Elastic modulus at temperature180.00 GPa
Thermal expansion coefficient1.3000e-05 1/K
Poisson's ratio0.30000 -
Stress concentration at grooves2.0000 -
Allowable thermal stress300.00 MPa

Applying the formula below gives:

ResultValue
Thermal diffusivity6.8681 mm²/s
Surface minus mean temperature145.60 K
Peak surface thermal stress973.44 MPa
Largest heating rate for the allowable0.92456 K/min

Open this example in the calculator and change any input.

Formula

\(\Delta T_{s-m} = \frac{\dot TR^2}{8a}, \quad \sigma_s = \frac{K_tE\alpha\Delta T_{s-m}}{1 - \nu}, \quad \dot T_{max} = \frac{8a\sigma_a(1 - \nu)}{K_tE\alpha R^2}\)

Variables

Symbol Meaning SI unit
\(R\) Rotor radius (solid) at the section m
\(\dot T\) Steam/surface heating rate K/s
\(k\) Rotor steel conductivity W/(m·K)
\(\rho\) Density kg/m³
\(c_p\) Specific heat J/(kg·K)
\(E\) Elastic modulus at temperature Pa
\(\alpha\) Thermal expansion coefficient 1/K
\(\nu\) Poisson's ratio -
\(K_t\) Stress concentration at grooves -
\(\sigma_a\) Allowable thermal stress Pa
\(a\) Thermal diffusivity m²/s
\(\Delta T_{s-m}\) Surface minus mean temperature K
\(\sigma_s\) Peak surface thermal stress Pa
\(\dot T_{max}\) Largest heating rate for the allowable K/s

Method and standards

Rotor stress.

Where it is used

  • Turbine start-up curve checks.
  • Cycling and fast-start studies.

Common mistakes

  • Using the steam rate instead of the metal surface rate.
  • Ignoring stress concentration at grooves.

Assumptions and limits

  • Solid cylinder; quasi-steady heating; constant properties.

References

  • Quasi-steady radial conduction and thermal stress in a cylinder

Questions and answers

Why are big turbines started slowly?

Their thick rotors heat from the surface; fast heating builds a large surface-to-core difference and high stress at grooves.

Is cooling worse than heating?

Often yes: cooling puts the surface in tension, which is more damaging to grooves and fillets.

What do the defaults represent?

An illustrative 400 mm radius rotor heated at 3 K/min with K_t = 2 and a 300 MPa allowable thermal stress.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Timoshenko and Goodier, Theory of Elasticity, 3rd ed. (McGraw-Hill, 1970), Leizerovich, Steam Turbines for Modern Fossil-Fuel Power Plants (Fairmont Press, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.