Worked example
Example: Bagasse with 15 % coal. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam | 60.000 t/h |
| Steam pressure (absolute) | 46.000 bar |
| Steam temperature | 440.00 °C |
| Feedwater temperature | 105.00 °C |
| Boiler efficiency (on the basis of the emission factors) | 80.000 % |
| Fossil share of heat input | 15.000 % |
| Fossil emission factor | 94.600 t/TJ |
| Biogenic emission factor | 100.00 t/TJ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel heat input | 59.492 MW |
| Fossil CO₂ | 3.0391 t/h |
| Fossil CO₂ per tonne of steam | 50.652 kg/t |
| Biogenic CO₂ (reported separately) | 18.205 t/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \frac{\dot m_s (h_s - h_{fw})}{\eta}, \quad \dot m_{CO_2,f} = \dot Q f EF_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Steam | kg/s |
| \(p\) | Steam pressure (absolute) | Pa |
| \(T\) | Steam temperature | K |
| \(T_{fw}\) | Feedwater temperature | K |
| \(\eta\) | Boiler efficiency (on the basis of the emission factors) | - |
| \(f\) | Fossil share of heat input | - |
| \(EF_f\) | Fossil emission factor | kg/J |
| \(EF_b\) | Biogenic emission factor | kg/J |
| \(\dot Q\) | Fuel heat input | W |
| \(\dot m_{CO_2,f}\) | Fossil CO₂ | kg/s |
| \(e_f\) | Fossil CO₂ per tonne of steam | kg/kg |
| \(\dot m_{CO_2,b}\) | Biogenic CO₂ (reported separately) | kg/s |
Method and standards
Energy balance: fuel heat is the heat to the steam (IAPWS-IF97 enthalpies) over the efficiency; CO₂ is the heat times each share and its emission factor.
Where it is used
- Carbon accounting.
- Fuel switching studies.
Common mistakes
- Gross efficiency with net factors.
Assumptions and limits
- Steady output.
- All the non-fossil heat input is taken as biogenic; other non-fossil heat (electric, waste heat) must be removed from the shares first.
- The efficiency must be on the same calorific basis as the emission factors (net for IPCC defaults).
- Steam must be superheated and feedwater liquid at the steam pressure.
References
- Fuel heat from IAPWS-IF97 enthalpies and efficiency; emission factors per TJ (IPCC 2006 Vol. 2 defaults as user inputs)
Questions and answers
Why separate biogenic CO₂?
Carbon from bagasse was absorbed by the cane; inventories report it apart from fossil CO₂.
Which emission factor?
Your fuel's factor, or IPCC defaults per TJ on net calorific value.
Net or gross efficiency?
Match the factors: IPCC factors are on net calorific value.