Worked example
Example: Day: steam 15 230 to 15 430 t, coal 33 t, feed 16 100 to 16 312 t, 22 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam totaliser, start | 15,230 t |
| Steam totaliser, end | 15,430 t |
| Feedwater totaliser, start | 16,100 t |
| Feedwater totaliser, end | 16,312 t |
| Steam totaliser roll-over value (0 = none) | 0 t |
| Feedwater totaliser roll-over value (0 = none) | 0 t |
| Fuel burned | 33.000 t |
| Running hours | 22.000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam generated | 200.00 t |
| Feedwater supplied | 212.00 t |
| Average steam flow | 9,090.9 kg/h |
| Average fuel flow | 1,500.0 kg/h |
| Steam per kg of fuel | 6.0606 kg/kg |
| Feedwater not leaving as steam (blowdown, leaks, meter error) | 12.000 t |
| Same, share of feedwater | 5.6604 % |
Open this example in the calculator and change any input.
Formula
\(S = S_1 - S_0\ (+\,S_{max}\ \text{after a roll-over}) \qquad W = W_1 - W_0\ (+\,W_{max}) \qquad \bar S = \frac{S}{t_r} \qquad \bar F = \frac{F}{t_r} \qquad \frac{S}{F} \qquad d = \frac{W - S}{W}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_0\) | steam totaliser, start | kg |
| \(S_1\) | steam totaliser, end | kg |
| \(W_0\) | feedwater totaliser, start | kg |
| \(W_1\) | feedwater totaliser, end | kg |
| \(S_{max}\), \(W_{max}\) | totaliser roll-over values (0 = none) | kg |
| \(F\) | fuel burned | kg |
| \(t_r\) | running hours | s |
| \(S\) | steam generated | kg |
| \(W\) | feedwater supplied | kg |
| \(\bar S\) | average steam flow | kg/s |
| \(\bar F\) | average fuel flow | kg/s |
| \(S/F\) | steam per kg of fuel | kg/kg |
| \(W - S\) | feedwater not leaving as steam | kg |
| \(d\) | same, share of feedwater | – |
Method and standards
Differences of totaliser readings over the shift or day; averages over the running hours.
Where it is used
- Shift and daily boiler log sheets.
- Spotting meter faults and water losses.
- Feeding monthly efficiency and cost reports.
Common mistakes
- Forgetting totaliser roll-over.
- Using calendar hours instead of running hours for averages.
- Not correcting steam meters for pressure.
Assumptions and limits
- Meters read at the same times; fuel burned from weighing or stock change.
- A totaliser that rolled over once during the period is handled when its roll-over value is entered.
- A warning appears when more than 10 % of the feedwater did not leave as steam.
References
- Totaliser differences and averages (definitions)
Questions and answers
How do I make a daily boiler report from the meters?
Subtract start from end readings. Steam from 15 230 to 15 430 t is 200 t; feedwater from 16 100 to 16 312 t is 212 t; with 33 t of coal in 22 hours that is 9.1 t/h of steam, 1.5 t/h of coal and 6.06 kg of steam per kg.
Why is feedwater more than steam?
Blowdown, vents, leaks and meter error. Here 12 t, 5.7 % of feedwater; compare it with the blowdown you expect.
What if steam reads more than feedwater?
A meter is wrong, often a steam meter without pressure correction.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.