FireCADCalc

Turbine Spiral Case Inlet Size and Section Areas

Spiral case inlet velocity from a velocity coefficient and net head, the inlet area and diameter, and section areas around the spiral for uniform flow distribution.

Thermal power plant

Inputs

Examples: Illustrative 40 m3/s at 80 mHigh head 12 m3/s at 300 mLow head 120 m3/s at 25 m

Accepted: 360 to 3,600,000 m³/h
Accepted: 5 to 1,000 m
Accepted: 0.05 to 0.4
Accepted: 179.91 to 360.96 °

Results

Constant mean velocity around the spiral: each section carries the flow not yet delivered to the stay vanes, so area falls linearly with angle: A(φ) = A_in(1 − φ/θ_wrap). Velocity coefficients of about 0.15–0.25 are common for Francis spirals; designs following free-vortex (constant angular momentum) give slightly different areas. Final shapes come from model tests.

Inlet velocity4.8716m/s
Inlet area24.633m²
Inlet diameter (circular)5,600.3mm
Section area 90° from the inlet17.915m²
Section area 180° from the inlet11.197m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 40 m3/s at 80 m. The inputs, in the units selected above:

InputValue
Rated flow144,000 m³/h
Net head80.000 m
Inlet velocity coefficient (v = K_v√(2gH))0.18000 -
Wrap angle345.00 °

Applying the formula below gives:

ResultValue
Inlet velocity7.1301 m/s
Inlet area5.6101 m²
Inlet diameter (circular)2,672.6 mm
Section area 90° from the inlet4.1466 m²
Section area 180° from the inlet2.6831 m²

Open this example in the calculator and change any input.

Formula

\(v_{in} = K_v\sqrt{2gH}, \quad A_{in} = \frac{Q}{v_{in}}, \quad A(\varphi) = A_{in}\left(1 - \frac{\varphi}{\theta_{wrap}}\right)\)

Variables

Symbol Meaning SI unit
\(Q\) Rated flow m³/s
\(H\) Net head m
\(K_v\) Inlet velocity coefficient (v = K_v√(2gH)) -
\(\theta_{wrap}\) Wrap angle rad
\(v_{in}\) Inlet velocity m/s
\(A_{in}\) Inlet area m²
\(D_{in}\) Inlet diameter (circular) m
\(A_{90}\) Section area 90° from the inlet m²
\(A_{180}\) Section area 180° from the inlet m²

Method and standards

Spiral case.

Where it is used

  • Preliminary hydro turbine layout.
  • Comparing intake and penstock sizes.

Common mistakes

  • Using gross head.
  • Applying high-head coefficients to low-head units.

Assumptions and limits

  • Constant mean velocity; uniform outflow to the stay vanes.

References

  • Constant-velocity spiral case sizing

Questions and answers

Why does the spiral cross-section shrink?

Flow leaves into the stay vanes all round, so each successive section carries less flow at the same velocity.

Why are steel spirals used for high heads?

They contain high pressure; low-head plants often use concrete semi-spirals with lower velocities.

What do the defaults represent?

An illustrative Francis unit with 40 m³/s at 80 m net head, K_v = 0.18, 345° wrap.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Gulliver and Arndt, Hydropower Engineering Handbook (McGraw-Hill, 1991)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.