FireCADCalc

Francis Turbine Velocity Triangles, Blade Angles and Efficiency

Inlet and outlet velocity triangles, guide vane and blade angles, Euler work, hydraulic efficiency and power of a Francis runner with radial discharge.

Thermal power plant

Inputs

Examples: 2.0 m runner, 12 m3/s, 60 m, 250 rpm, guide vanes 18 degMedium head 120 m, 8 m3/s, 428.6 rpm, 1.6 m runner, 14 degLow head 25 m, 30 m3/s, 150 rpm, 3 m runner, 30 deg

Accepted: 5 to 700 m
Accepted: 36 to 3,600,000 m³/h
Accepted: 95.493 to 14,324 rpm
Accepted: 0.1 to 15 m
Accepted: 0.01 to 5 m
Accepted: 0.1 to 15 m
Accepted: 0.01 to 5 m
Accepted: 3 to 60 °
Accepted: 80 to 100 %
Accepted: 990 to 1,030 kg/m³

Results

Radial (whirl-free) discharge is assumed, so the Euler work is u₁V_w1. A blade inlet angle above 90° marks a fast runner.

Runner inlet peripheral speed23.562m/s
Inlet flow velocity4.1019m/s
Inlet whirl velocity7.1048m/s
Absolute inlet velocity8.2039m/s
Runner blade inlet angle166.00°
Outlet peripheral speed18.850m/s
Outlet flow velocity4.1019m/s
Runner blade outlet angle12.277°
Hydraulic efficiency u₁V_w1/(gH)68.281%
Power developed by the runner5,022.1kW
Speed ratio1.0641
Flow ratio0.18524

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2.0 m runner, 12 m3/s, 60 m, 250 rpm, guide vanes 18 deg. The inputs, in the units selected above:

InputValue
Net head60.000 m
Flow43,200 m³/h
Speed250.00 rpm
Runner inlet diameter2.0000 m
Runner inlet width0.30000 m
Runner outlet diameter1.4000 m
Runner outlet width (axial area = πD₂B₂)0.50000 m
Guide vane angle18.000 °
Area factor for blade thickness95.000 %
Water density1,000.0 kg/m³

Applying the formula below gives:

ResultValue
Runner inlet peripheral speed26.180 m/s
Inlet flow velocity6.7013 m/s
Inlet whirl velocity20.624 m/s
Absolute inlet velocity21.686 m/s
Runner blade inlet angle129.66 °
Outlet peripheral speed18.326 m/s
Outlet flow velocity5.7439 m/s
Runner blade outlet angle17.403 °
Hydraulic efficiency u₁V_w1/(gH)91.765 %
Power developed by the runner6,479.3 kW
Speed ratio0.76316
Flow ratio0.19535

Open this example in the calculator and change any input.

Formula

\(u = \frac{\pi DN}{60}, \quad V_f = \frac{Q}{k\pi DB}, \quad V_{w1} = \frac{V_{f1}}{\tan\alpha_1}, \quad \tan\beta_1 = \frac{V_{f1}}{V_{w1} - u_1}, \quad \tan\beta_2 = \frac{V_{f2}}{u_2}\)

\(\eta_h = \frac{u_1V_{w1}}{gH}, \quad P = \rho Qu_1V_{w1}\)

Variables

Symbol Meaning SI unit
\(H\) Net head m
\(Q\) Flow m³/s
\(N\) Speed rad/s
\(D_1\) Runner inlet diameter m
\(B_1\) Runner inlet width m
\(D_2\) Runner outlet diameter m
\(B_2\) Runner outlet width (axial area = πD₂B₂) m
\(\alpha_1\) Guide vane angle rad
\(k\) Area factor for blade thickness -
\(\rho\) Water density kg/m³
\(u_1\) Runner inlet peripheral speed m/s
\(V_{f1}\) Inlet flow velocity m/s
\(V_{w1}\) Inlet whirl velocity m/s
\(V_1\) Absolute inlet velocity m/s
\(\beta_1\) Runner blade inlet angle rad
\(u_2\) Outlet peripheral speed m/s
\(V_{f2}\) Outlet flow velocity m/s
\(\beta_2\) Runner blade outlet angle rad
\(\eta_h\) Hydraulic efficiency u₁V_w1/(gH) -
\(P\) Power developed by the runner W
\(u_1/\sqrt{2gH}\) Speed ratio -
\(V_{f1}/\sqrt{2gH}\) Flow ratio -

Method and standards

Euler turbine equation with one-dimensional velocity triangles.

Where it is used

  • Checking runner and guide vane geometry.
  • Student and exam calculations on reaction turbines.

Common mistakes

  • Measuring blade angles from the radial direction instead of the blade motion.
  • Using the gross head.

Assumptions and limits

  • One-dimensional flow, radial discharge.

Questions and answers

What is radial discharge?

Water leaves the runner with no whirl (V_w2 = 0), so all of its swirl is converted to work; real runners leave a little swirl at part load.

Which speed and flow ratios are usual?

Speed ratio u₁/√(2gH) of about 0.6–0.9 and flow ratio 0.15–0.3 for Francis runners.

What do the defaults represent?

A runner 2.0 m by 0.30 m wide at the inlet and 1.4 m at the outlet, 12 m³/s under 60 m at 250 rpm with 18° guide vanes and a 0.95 thickness factor.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), ch. 10 (reaction turbines, velocity triangles and Euler equation)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.