FireCADCalc

Organic Rankine Cycle Power from Low-Grade Heat

Carnot limit and estimated ORC net power from a heat source's flow and temperatures and the cooling temperature, as a share of Carnot between mean temperatures.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserFood, dairy and textile

Inputs

Examples: 10 kg/s gas 300 → 120 °CHot water 150 → 90 °C

Results

Commercial ORC units reach 10–20 % net efficiency from 150–300 °C sources; ask the maker for a firm figure.

Heat taken from the source7,560.0kW
Mean source temperature119.24°C
Carnot efficiency between mean and cooling temperature22.742%
Estimated ORC efficiency10.234%
Estimated net power (the Carnot share covers all losses)773.68kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 kg/s gas 300 → 120 °C. The inputs, in the units selected above:

InputValue
Heat source flow36,000 kg/h
Source specific heat1.1000 kJ/(kg·K)
Source in300.00 °C
Source out120.00 °C
Cooling (condensing) temperature35.000 °C
Share of Carnot achieved50.000 %

Applying the formula below gives:

ResultValue
Heat taken from the source1,980.0 kW
Mean source temperature204.36 °C
Carnot efficiency between mean and cooling temperature35.467 %
Estimated ORC efficiency17.734 %
Estimated net power (the Carnot share covers all losses)351.13 kW

Open this example in the calculator and change any input.

Formula

\(T_m = \frac{T_1 - T_2}{\ln(T_1/T_2)}, \quad \eta_C = 1 - \frac{T_c}{T_m}, \quad P = f\eta_C\,\dot mc_p(T_1 - T_2)\)

Variables

Symbol Meaning SI unit
\(\dot m\) Heat source flow kg/s
\(c_p\) Source specific heat J/(kg·K)
\(T_1\) Source in K
\(T_2\) Source out K
\(T_c\) Cooling (condensing) temperature K
\(f\) Share of Carnot achieved -
\(Q\) Heat taken from the source W
\(T_m\) Mean source temperature K
\(\eta_C\) Carnot efficiency between mean and cooling temperature -
\(\eta\) Estimated ORC efficiency -
\(P\) Estimated net power W

Method and standards

Second-law estimate: Carnot efficiency between the source's thermodynamic mean temperature and the cooling temperature, times the share of Carnot you enter. That share stands for all real losses, pump and fan power included; nothing else is deducted.

Where it is used

  • Screening ORC projects.

Common mistakes

  • Using Carnot efficiency as achievable.
  • Cooling the source below its dew point.

Assumptions and limits

  • Constant specific heat.
  • The source outlet temperature is not checked against the acid dew point of a flue gas or the ORC evaporator pinch: choose it with both in mind.

References

  • Carnot efficiency between the source's thermodynamic mean temperature (T₁ − T₂)/ln(T₁/T₂) and the cooling temperature (second law)

Questions and answers

Why the log-mean source temperature?

A source cooled from T₁ to T₂ gives heat at that thermodynamic average for entropy purposes.

What share of Carnot is realistic?

40–60 % for good ORC plants.

Why not steam?

Below about 300 °C organic fluids make smaller, simpler turbines than steam.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.