Worked example
Example: GT exhaust 100 kg/s from 550 to 750 °C, natural gas 47 MJ/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Exhaust gas flow | 360,000 kg/h |
| Mean specific heat of the gas between T₁ and T₂ | 1.1800 kJ/(kg·K) |
| Gas temperature before the burner | 550.00 °C |
| Gas temperature after firing | 750.00 °C |
| Net calorific value of the fuel | 47,000 kJ/kg |
| Burner (combustion) efficiency | 99.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel needed | 1,825.9 kg/h |
| Heat added to the gas | 23.600 MW |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_g\,c_{p,g}\,(T_2 - T_1) \qquad \dot m_f = \frac{\dot Q}{NCV\,\eta_b}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | exhaust gas flow | kg/s |
| \(c_{p,g}\) | mean gas specific heat between T₁ and T₂ | J/(kg·K) |
| \(T_1\) | temperature before firing | K |
| \(T_2\) | temperature after firing | K |
| \(NCV\) | net calorific value of the fuel | J/kg |
| \(\eta_b\) | burner efficiency | – |
| \(\dot m_f\) | fuel needed | kg/s |
| \(\dot Q\) | heat added | W |
Method and standards
Energy balance of the exhaust with a mean specific heat; the small mass of fuel added is neglected.
Where it is used
- Sizing duct burners.
- Fuel budgets of fired HRSGs.
- Comparing fired and unfired operation.
Common mistakes
- Using GCV instead of NCV.
- Forgetting the O₂ left after firing (minimum for stable flames).
- Firing above the duct liner temperature limit.
Assumptions and limits
- Constant gas specific heat (the mean between T₁ and T₂); fuel mass neglected.
- The O₂ left after firing is not calculated (the exhaust analysis and fuel are not inputs): check with the combustion or flue gas calculators, and with the burner maker, that enough O₂ remains for the fired temperature.
References
- Energy balance of the exhaust gas
Questions and answers
How much gas does a duct burner need?
Raising 100 kg/s of exhaust from 550 to 750 °C takes 23.6 MW; with natural gas of 47 MJ/kg NCV and 99 % burner efficiency that is about 1830 kg/h.
Why can exhaust be fired without fresh air?
Gas turbine exhaust still holds most of its oxygen, about 13–16 %, enough to burn extra fuel.
Why fire at all?
To make more steam, or steam at a higher pressure, than the exhaust alone gives, at an efficiency close to 100 % for the extra fuel.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.