FireCADCalc

Exhaust Gas Heater for Hot Water or Thermic Fluid

Heat from an exhaust cooled to a stack limit, the hot water or thermic fluid flow it heats through a temperature rise, and the cold-end approach check.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserFood, dairy and textileThermic fluid heater

Inputs

Examples: Thermic fluid 150 → 280 °CHot water 70 → 90 °C

Water about 4.19, thermic fluids 2.2–2.8 kJ/(kg·K).

Results

Check the exhaust outlet against its acid dew point and the thermic fluid film temperature in the hottest rows; neither is checked here.

Heat transferred1,711.1kW
Liquid flow73.508t/h
Cold-end approach (counter-flow)50.000K
Hot-end approach310.00K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Thermic fluid 150 → 280 °C. The inputs, in the units selected above:

InputValue
Exhaust flow11,000 kg/h
Exhaust specific heat1.1000 kJ/(kg·K)
Exhaust in450.00 °C
Exhaust out230.00 °C
Liquid specific heat2.5000 kJ/(kg·K)
Liquid in150.00 °C
Liquid out280.00 °C

Applying the formula below gives:

ResultValue
Heat transferred739.44 kW
Liquid flow8.1908 t/h
Cold-end approach (counter-flow)80.000 K
Hot-end approach170.00 K

Open this example in the calculator and change any input.

Formula

\(Q = \dot m_gc_{pg}(T_{g1} - T_{g2}), \quad \dot m_l = \frac{Q}{c_{pl}(T_{l2} - T_{l1})}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Exhaust flow kg/s
\(c_{pg}\) Exhaust specific heat J/(kg·K)
\(T_{g1}\) Exhaust in K
\(T_{g2}\) Exhaust out K
\(c_{pl}\) Liquid specific heat J/(kg·K)
\(T_{l1}\) Liquid in K
\(T_{l2}\) Liquid out K
\(Q\) Heat transferred W
\(\dot m_l\) Liquid flow kg/s
\(T_{g2} - T_{l1}\) Cold-end approach (counter-flow) K
\(T_{g1} - T_{l2}\) Hot-end approach K

Method and standards

Energy balance with approach checks.

Where it is used

  • Exhaust heaters on engines, turbines and kilns.

Common mistakes

  • A temperature cross.
  • Ignoring fluid film temperature limits.

Assumptions and limits

  • Counter-flow; no losses. A temperature cross at either end is rejected; a cold-end approach under 20 K gives a warning.
  • The acid dew point at the exhaust outlet and the thermic fluid film temperature are not checked.

References

  • Energy balances (definitions)

Questions and answers

Why thermic fluid instead of steam?

It reaches 250–300 °C at near-atmospheric pressure, without a pressurised drum.

What approach is practical?

20–40 K at the cold end for finned-tube exhaust heaters.

Is the film temperature a concern?

Yes: check the thermic fluid's film temperature in the hottest rows.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.