Worked example
Example: 250 kW screw, 75 %, 40 K rise. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor shaft power | 250.00 kW |
| Share of shaft power recoverable | 75.000 % |
| Water temperature rise | 40.000 K |
| Efficiency of the heater it replaces (same GCV or NCV basis as the fuel cost) | 85.000 % |
| Fuel cost per GJ of fuel heat | 500.00 - |
| Loaded hours per year | 6,000.0 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat recovered | 187.50 kW |
| Water heated | 4.0305 t/h |
| Annual fuel cost saved | 2,382,353 |
Open this example in the calculator and change any input.
Formula
\(Q = f_rP, \quad \dot m_w = \frac{Q}{c_w\Delta T_w}, \quad C = \frac{Q}{\eta_b}t\,c_f\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Compressor shaft power | W |
| \(f_r\) | Share of shaft power recoverable | - |
| \(\Delta T_w\) | Water temperature rise | K |
| \(\eta_b\) | Efficiency of the heater it replaces | - |
| \(c_f\) | Fuel cost per GJ, on the same GCV or NCV basis as \(\eta_b\) | - |
| \(c_w\) | specific heat of water, 4186.8 | J/(kg·K) |
| \(t\) | Loaded hours per year | s |
| \(Q\) | Heat recovered | W |
| \(\dot m_w\) | Water heated | kg/s |
| \(C\) | Annual fuel cost saved | - |
Method and standards
Energy balance.
Where it is used
- Compressor house energy projects.
Common mistakes
- Counting unloaded hours.
- No dump cooler for when heat is not needed.
Assumptions and limits
- Water c_p 4.1868 kJ/(kg·K).
- The recovered heat is assumed to be used in full during every loaded hour; if the hot-water demand is smaller or not coincident, the saving is smaller.
References
- Energy balances (definitions)
Questions and answers
Why can so much be recovered?
Nearly all the shaft power ends up as heat in the oil and air coolers.
What water temperature?
Up to 70–90 °C from oil-injected screws; enough for boiler feed or process washing.
Does it change compressor efficiency?
No, as long as cooling stays adequate when the heat is not needed.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.