Worked example
Example: Hot day 35 C, 1.005 bar: 70 kg/s, 3,000 rpm, 20 MW. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured inlet stagnation temperature | 35.000 °C |
| Measured inlet stagnation pressure | 1.0050 bar |
| Measured air flow | 70.000 kg/s |
| Measured shaft speed | 3,000.0 rpm |
| Measured shaft power (0 for a jet engine) | 20.000 MW |
| Measured fuel flow | 1.2500 kg/s |
| Measured exhaust gas temperature | 546.85 °C |
| Reference temperature (ISA 288.15 K) | 15.000 °C |
| Reference pressure (ISA 1.01325 bar) | 1.0132 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature ratio T₀₁/T_ref | 1.0694 |
| Pressure ratio p₀₁/p_ref | 0.99186 |
| Referred air flow | 72.983 kg/s |
| Referred speed | 2,901.0 rpm |
| Referred power | 19.499 MW |
| Referred fuel flow | 1.2187 kg/s |
| Referred exhaust temperature | 766.78 K |
Open this example in the calculator and change any input.
Formula
\(\theta = \frac{T_{01}}{T_{ref}}, \quad \delta = \frac{p_{01}}{p_{ref}}, \quad \dot m_{ref} = \frac{\dot m\sqrt\theta}{\delta}, \quad N_{ref} = \frac{N}{\sqrt\theta}\)
\(P_{ref} = \frac{P}{\delta\sqrt\theta}, \quad \dot m_{f,ref} = \frac{\dot m_f}{\delta\sqrt\theta}, \quad T_{ex,ref} = \frac{T_{ex}}{\theta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{01}\) | Measured inlet stagnation temperature | K |
| \(p_{01}\) | Measured inlet stagnation pressure | Pa |
| \(\dot m\) | Measured air flow | kg/s |
| \(N\) | Measured shaft speed | rad/s |
| \(P\) | Measured shaft power (0 for a jet engine) | W |
| \(\dot m_f\) | Measured fuel flow | kg/s |
| \(T_{ex}\) | Measured exhaust gas temperature | K |
| \(T_{ref}\) | Reference temperature (ISA 288.15 K) | K |
| \(p_{ref}\) | Reference pressure (ISA 1.01325 bar) | Pa |
| \(\theta\) | Temperature ratio T₀₁/T_ref | - |
| \(\delta\) | Pressure ratio p₀₁/p_ref | - |
| \(\dot m\sqrt\theta/\delta\) | Referred air flow | kg/s |
| \(N/\sqrt\theta\) | Referred speed | rad/s |
| \(P/(\delta\sqrt\theta)\) | Referred power | W |
| \(\dot m_f/(\delta\sqrt\theta)\) | Referred fuel flow | kg/s |
| \(T_{ex}/\theta\) | Referred exhaust temperature | K |
Method and standards
Referred (corrected) parameters from dimensional analysis.
Where it is used
- Trending gas turbine and compressor performance.
- Comparing acceptance test points taken at different ambients.
Common mistakes
- Using static instead of stagnation inlet conditions.
- Correcting speed with θ instead of √θ.
Assumptions and limits
- Constant γ; Reynolds number effects neglected.
Questions and answers
Why refer readings to ISA?
A gas turbine's behaviour depends on the non-dimensional groups, so readings on a hot day and a cold day collapse onto one curve when referred. That makes trends in degradation visible.
Is referred power the same as ISO-corrected power?
Not quite. ISO correction of a generator set at fixed speed also uses the maker's curves, because the referred speed changes with ambient temperature. Referred values are the starting point.
What do the defaults represent?
A hot day (35 °C, 1.005 bar): 70 kg/s, 3,000 rpm, 20 MW, 1.25 kg/s of fuel and an exhaust at 820 K.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 4.5 (non-dimensional groups) and ch. 8 (off-design performance)