Worked example
Example: Illustrative 50 MW at 35 C and 500 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| ISO rated output | 50.000 MW |
| ISO heat rate (LHV) | 10,000 kJ/kWh |
| Site ambient temperature | 35.000 °C |
| Site altitude | 500.00 m |
| Output loss per kelvin above 15 °C | 0.70000 % |
| Heat rate rise per kelvin above 15 °C | 0.18000 % |
| Extra inlet pressure loss | 500.00 Pa |
| Output loss per 1 kPa inlet loss | 1.5000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Site atmospheric pressure (ISA) | 95.461 kPa |
| Pressure factor | 0.94213 |
| Temperature factor on output | 0.86000 |
| Site output | 40.208 MW |
| Site heat rate | 10,360 kJ/kWh |
Open this example in the calculator and change any input.
Formula
\(P = P_{ISO}\frac{p_a}{101.325}\left[1 - k_P(T_a - 15)\right]\left(1 - k_{in}\Delta p_{in}\right), \quad HR = HR_{ISO}\left[1 + k_{HR}(T_a - 15)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_{ISO}\) | ISO rated output | W |
| \(HR_{ISO}\) | ISO heat rate (LHV) | J/J |
| \(T_a\) | Site ambient temperature | K |
| \(z\) | Site altitude | m |
| \(k_P\) | Output loss per kelvin above 15 °C | - |
| \(k_{HR}\) | Heat rate rise per kelvin above 15 °C | - |
| \(\Delta p_{in}\) | Extra inlet pressure loss | Pa |
| \(k_{in}\) | Output loss per 1 kPa inlet loss | - |
| \(p_a\) | Site atmospheric pressure (ISA) | Pa |
| \(f_p\) | Pressure factor | - |
| \(f_T\) | Temperature factor on output | - |
| \(P\) | Site output | W |
| \(HR\) | Site heat rate | J/J |
Method and standards
Site correction.
Where it is used
- Bidding site capacity.
- Assessing inlet cooling and filter changes.
Common mistakes
- Applying ISO output at a hot, high site.
- Using gauge for absolute pressure.
Assumptions and limits
- Linear corrections near ISO conditions.
References
- Linear site correction with ISO 2533 pressure
Questions and answers
Why does a gas turbine lose output on hot days?
Hot air is less dense, so the fixed-volume compressor pushes less mass, and compressor work per kg rises.
Does altitude change efficiency?
Hardly: output falls with pressure but so does fuel flow, leaving heat rate nearly unchanged.
What do the defaults represent?
An illustrative 50 MW unit with a 10,000 kJ/kWh heat rate at 35 °C and 500 m with 0.7 %/K and 0.18 %/K coefficients and 0.5 kPa extra inlet loss.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Boyce, Gas Turbine Engineering Handbook, 4th ed. (Butterworth-Heinemann, 2012), Kehlhofer, Hannemann, Stirnimann and Rukes, Combined-Cycle Gas and Steam Turbine Power Plants, 3rd ed. (PennWell, 2009)