FireCADCalc

Combustion Chamber Pressure Loss Factor (Cold and Hot Loss)

Fits the pressure loss factor PLF = K1 + K2(T02/T01 − 1) of a gas turbine combustor from a cold and a hot test and predicts the loss at another condition.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Annular chamber, PLF from test 18, overload 110 % flowCan chamber at idle

Accepted: 0.0001 to 10 m²
Accepted: 0.0001 to 20 m²
Accepted: 0 to 200
Accepted: 0.01 to 2,000 kg/s
Accepted: -23.15 to 926.85 °C
Accepted: -23.15 to 1,926.8 °C
Accepted: 0.5 to 60 bar
Accepted: 1E-5 to 10 bar
Accepted: 0.01 to 2,000 kg/s
Accepted: -23.15 to 926.85 °C
Accepted: -23.15 to 1,926.8 °C
Accepted: 0.5 to 60 bar
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 0.25 to 0.32 kJ/(kg·K)

Results

The dynamic head uses the reference velocity: inlet density, air mass flow and the maximum chamber area. Typical design PLF: tubular about 35, tubo-annular 25, annular 18.

Test: inlet velocity23.903m/s
Test: pressure loss factor144.58
Hot (fundamental) loss coefficient99.653
Test: loss as a fraction of inlet stagnation pressure4.9901%
Operating: inlet velocity22.945m/s
Operating: pressure loss factor99.740
Operating: stagnation pressure loss0.099329bar
Operating: loss as a fraction of inlet stagnation pressure3.9640%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Annular chamber, PLF from test 18, overload 110 % flow. The inputs, in the units selected above:

InputValue
Chamber inlet area0.30000 m²
Maximum cross-sectional area0.55000 m²
Cold loss coefficient (from a cold run)12.000 -
Test: air mass flow60.000 kg/s
Test: inlet stagnation temperature426.85 °C
Test: outlet stagnation temperature1,226.8 °C
Test: inlet static pressure15.000 bar
Test: stagnation pressure loss0.45000 bar
Operating: air mass flow66.000 kg/s
Operating: inlet stagnation temperature441.85 °C
Operating: outlet stagnation temperature1,276.8 °C
Operating: inlet static pressure16.200 bar
Air specific heat1.0050 kJ/(kg·K)
Air ratio of specific heats1.4000 -
Air gas constant0.28700 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Test: inlet velocity26.773 m/s
Test: pressure loss factor56.493
Hot (fundamental) loss coefficient38.932
Test: loss as a fraction of inlet stagnation pressure2.9947 %
Operating: inlet velocity27.852 m/s
Operating: pressure loss factor57.466
Operating: stagnation pressure loss0.52382 bar
Operating: loss as a fraction of inlet stagnation pressure3.2273 %

Open this example in the calculator and change any input.

Formula

\(PLF = \frac{\Delta p_0}{\dot m^2/(2\rho_1A_m^2)} = K_1 + K_2\left(\frac{T_{02}}{T_{01}} - 1\right)\)

Variables

Symbol Meaning SI unit
\(A_1\) Chamber inlet area m²
\(A_m\) Maximum cross-sectional area m²
\(K_1\) Cold loss coefficient (from a cold run) -
\(\dot m_d\) Test: air mass flow kg/s
\(T_{01,d}\) Test: inlet stagnation temperature K
\(T_{02,d}\) Test: outlet stagnation temperature K
\(p_{1,d}\) Test: inlet static pressure Pa
\(\Delta p_{0,d}\) Test: stagnation pressure loss Pa
\(\dot m\) Operating: air mass flow kg/s
\(T_{01}\) Operating: inlet stagnation temperature K
\(T_{02}\) Operating: outlet stagnation temperature K
\(p_1\) Operating: inlet static pressure Pa
\(c_p\) Air specific heat J/(kg·K)
\(\gamma\) Air ratio of specific heats -
\(R\) Air gas constant J/(kg·K)
\(C_{1,d}\) Test: inlet velocity m/s
\(PLF_d\) Test: pressure loss factor -
\(K_2\) Hot (fundamental) loss coefficient -
\(\Delta p_0/p_{01}\) Test: loss as a fraction of inlet stagnation pressure -
\(C_1\) Operating: inlet velocity m/s
\(PLF\) Operating: pressure loss factor -
\(\Delta p_0\) Operating: stagnation pressure loss Pa

Method and standards

Combustor pressure loss correlation from cold and hot tests.

Where it is used

  • Predicting combustor loss over the operating range from rig tests.
  • Cycle calculations at part load.

Common mistakes

  • Using the inlet area instead of the maximum area in the dynamic head.
  • Using stagnation instead of static inlet pressure for the density.

Assumptions and limits

  • One chamber geometry; Reynolds number effects neglected.

Questions and answers

What do the defaults represent?

An illustrative case: Annular chamber, PLF from test 18, overload 110 % flow. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 6.5, eq. 6.1 and problem 6.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.