Worked example
Example: Annular chamber, PLF from test 18, overload 110 % flow. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Chamber inlet area | 0.30000 m² |
| Maximum cross-sectional area | 0.55000 m² |
| Cold loss coefficient (from a cold run) | 12.000 - |
| Test: air mass flow | 60.000 kg/s |
| Test: inlet stagnation temperature | 426.85 °C |
| Test: outlet stagnation temperature | 1,226.8 °C |
| Test: inlet static pressure | 15.000 bar |
| Test: stagnation pressure loss | 0.45000 bar |
| Operating: air mass flow | 66.000 kg/s |
| Operating: inlet stagnation temperature | 441.85 °C |
| Operating: outlet stagnation temperature | 1,276.8 °C |
| Operating: inlet static pressure | 16.200 bar |
| Air specific heat | 1.0050 kJ/(kg·K) |
| Air ratio of specific heats | 1.4000 - |
| Air gas constant | 0.28700 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Test: inlet velocity | 26.773 m/s |
| Test: pressure loss factor | 56.493 |
| Hot (fundamental) loss coefficient | 38.932 |
| Test: loss as a fraction of inlet stagnation pressure | 2.9947 % |
| Operating: inlet velocity | 27.852 m/s |
| Operating: pressure loss factor | 57.466 |
| Operating: stagnation pressure loss | 0.52382 bar |
| Operating: loss as a fraction of inlet stagnation pressure | 3.2273 % |
Open this example in the calculator and change any input.
Formula
\(PLF = \frac{\Delta p_0}{\dot m^2/(2\rho_1A_m^2)} = K_1 + K_2\left(\frac{T_{02}}{T_{01}} - 1\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_1\) | Chamber inlet area | m² |
| \(A_m\) | Maximum cross-sectional area | m² |
| \(K_1\) | Cold loss coefficient (from a cold run) | - |
| \(\dot m_d\) | Test: air mass flow | kg/s |
| \(T_{01,d}\) | Test: inlet stagnation temperature | K |
| \(T_{02,d}\) | Test: outlet stagnation temperature | K |
| \(p_{1,d}\) | Test: inlet static pressure | Pa |
| \(\Delta p_{0,d}\) | Test: stagnation pressure loss | Pa |
| \(\dot m\) | Operating: air mass flow | kg/s |
| \(T_{01}\) | Operating: inlet stagnation temperature | K |
| \(T_{02}\) | Operating: outlet stagnation temperature | K |
| \(p_1\) | Operating: inlet static pressure | Pa |
| \(c_p\) | Air specific heat | J/(kg·K) |
| \(\gamma\) | Air ratio of specific heats | - |
| \(R\) | Air gas constant | J/(kg·K) |
| \(C_{1,d}\) | Test: inlet velocity | m/s |
| \(PLF_d\) | Test: pressure loss factor | - |
| \(K_2\) | Hot (fundamental) loss coefficient | - |
| \(\Delta p_0/p_{01}\) | Test: loss as a fraction of inlet stagnation pressure | - |
| \(C_1\) | Operating: inlet velocity | m/s |
| \(PLF\) | Operating: pressure loss factor | - |
| \(\Delta p_0\) | Operating: stagnation pressure loss | Pa |
Method and standards
Combustor pressure loss correlation from cold and hot tests.
Where it is used
- Predicting combustor loss over the operating range from rig tests.
- Cycle calculations at part load.
Common mistakes
- Using the inlet area instead of the maximum area in the dynamic head.
- Using stagnation instead of static inlet pressure for the density.
Assumptions and limits
- One chamber geometry; Reynolds number effects neglected.
Questions and answers
What do the defaults represent?
An illustrative case: Annular chamber, PLF from test 18, overload 110 % flow. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 6.5, eq. 6.1 and problem 6.3