Worked example
Example: 100 TCH, 54 and 21 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 100.00 t/h |
| Imbibition water per tonne cane | 0.30000 m³/t |
| Vapour to the condensers per tonne cane | 300.00 kg/t |
| Vapour temperature | 54.000 °C |
| Cold water temperature | 21.000 °C |
| Margin on condenser water | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Process water (bearings, filters, cooling, centrifugals, boilers) | 97.000 m³/h |
| Imbibition water | 30.000 m³/h |
| Water per kg vapour 650/(t_v − t₁) | 19.697 |
| Condenser cold water | 886.36 m³/h |
| Condenser water per tonne cane | 8.8636 m³/t |
Open this example in the calculator and change any input.
Formula
\(\dot V_p = 0.97A, \quad W = \frac{650}{t_v - t_1}, \quad \dot V_c = k\,W\,Q\,A\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(w\) | Imbibition water per tonne cane | m³/kg |
| \(Q\) | Vapour to the condensers per tonne cane | kg/kg |
| \(t_v\) | Vapour temperature | K |
| \(t_1\) | Cold water temperature | K |
| \(k\) | Margin on condenser water | - |
| \(\dot V_p\) | Process water (bearings, filters, cooling, centrifugals, boilers) | m³/s |
| \(\dot V_i\) | Imbibition water | m³/s |
| \(W\) | Water per kg vapour 650/(t_v − t₁) | - |
| \(\dot V_c\) | Condenser cold water | m³/s |
| \(\dot V_c/A\) | Condenser water per tonne cane | m³/kg |
Method and standards
Hugot's coefficients and condenser balance.
Where it is used
- Water supply planning.
- ZLD and recycling studies.
Common mistakes
- Counting imbibition twice.
- Using a single condenser margin for all designs.
Assumptions and limits
- Raw sugar factory with crystallisers cooled by water.
- W = 650/(t_v − t₁) assumes the water leaves at the vapour temperature (no approach); the margin k must cover the real approach.
- With no crush the water per tonne is not shown.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 40
- factory water requirements
- eqns 40.27–40.30 and p. 891
Questions and answers
Why so much condenser water?
About 20 kg of water per kg of vapour at a 33 °C range; 300 kg of vapour per tonne cane needs about 6 m³ of water.
Where does process water come from?
Mostly from vapour condensates; fresh water is needed mainly for make-up and the condensers.
Why margins?
Hugot: allow 30Q for central and 60Q for individual condensers to cope with peaks and warm water.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.