FireCADCalc

Condenser Air Pump: Air Volume and Ejector Steam

Air to remove from a condenser from vapour condensed and air per kg (Hugot Table 40.16), its volume at the outlet, pump size and ejector steam.

Sugar mill and cogenerationPump

Inputs

Examples: Hugot pan example: 25 200 kg/h, 6 g/kg, 30 °CEvaporator condenser

Hugot: central condensers 8–10 g/kg, multiple effects 6–8, pans 5–6.
Hugot: two-stage ejector at 6 kg/cm² and 66 cm vacuum about 2.5 + 6 = 8.5 kg/kg.

Results

Hugot's example: 25 200 kg/h of pan vapour at 6 g/kg, 66 cm vacuum and 30 °C air needs about 24 m³/min at the air outlet.

Dry air151.20kg/h
Vapour pressure at t_a4.2467kPa
Partial pressure of air9.0904kPa
Specific volume of the air9.5724m³/kg
Air volume at the outlet24.123m³/min
Pump displacement34.461m³/min
Steam for a steam-jet ejector1,285.2kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot pan example: 25 200 kg/h, 6 g/kg, 30 °C. The inputs, in the units selected above:

InputValue
Vapour condensed25,200 kg/h
Air per kg vapour6.0000 g/kg
Condenser pressure (absolute)13.337 kPa
Air temperature at the air outlet30.000 °C
Volumetric efficiency of the pump70.000 %
Ejector steam per kg of dry air8.5000 -

Applying the formula below gives:

ResultValue
Dry air151.20 kg/h
Vapour pressure at t_a4.2467 kPa
Partial pressure of air9.0904 kPa
Specific volume of the air9.5724 m³/kg
Air volume at the outlet24.123 m³/min
Pump displacement34.461 m³/min
Steam for a steam-jet ejector1,285.2 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_a = aG, \quad p_a = p - p_{sat}(t_a), \quad v_a = \frac{R_a T_a}{p_a}, \quad \dot V_a = \dot m_a v_a, \quad \dot V_d = \frac{\dot V_a}{\eta_v}\)

Variables

Symbol Meaning SI unit
\(G\) Vapour condensed kg/s
\(a\) Air per kg vapour kg/kg
\(p\) Condenser pressure (absolute) Pa
\(t_a\) Air temperature at the air outlet K
\(\eta_v\) Volumetric efficiency of the pump -
\(s_e\) Ejector steam per kg of dry air -
\(\dot m_a\) Dry air kg/s
\(p_v\) Vapour pressure at t_a Pa
\(p_a\) Partial pressure of air Pa
\(v_a\) Specific volume of the air m³/kg
\(\dot V_a\) Air volume at the outlet m³/s
\(\dot V_d\) Pump displacement m³/s
\(\dot m_s\) Steam for a steam-jet ejector kg/s

Method and standards

Dalton's and Mariotte's laws as used by Hugot.

Where it is used

  • Sizing vacuum pumps and ejectors.
  • Diagnosing poor vacuum.

Common mistakes

  • Using condenser pressure as air pressure.
  • Ignoring the air from leaks.

Assumptions and limits

  • Saturated air at t_a. As t_a approaches the saturation temperature at p the air partial pressure tends to zero and the volume grows without limit; a note warns when the air is below a quarter of p.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 40
  • air extraction (Tables 40.9–40.16, Mariotte's law, example p. 878) and ejectors
  • pp. 867–880 and 901–903
  • Gas constant of dry air from CODATA R and the air composition

Questions and answers

Why so much volume for so little air?

At 10 kPa the air is a tenth of atmospheric density, and the vapour mixed with it lowers its partial pressure further.

Why cool the air before the pump?

Colder air carries less vapour and has a higher partial pressure, so the pump handles less volume.

Liquid-ring or ejector?

Liquid-ring pumps use about an eighth of the energy of steam ejectors (Hugot).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.