Worked example
Example: 1,480 rpm on 5 Hz mounts, ζ 0.05. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Disturbing (running) frequency | 1,480.0 rpm |
| Mounted natural frequency | 5.0000 Hz |
| Damping ratio | 5.0000 % |
| Target isolation efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Frequency ratio f/f_n | 4.9333 |
| Transmissibility | 0.047769 |
| Isolation efficiency | 95.223 % |
| Natural frequency for the target (undamped) | 7.4373 Hz |
| Static deflection for the target | 4.4909 mm |
Open this example in the calculator and change any input.
Formula
\(TR = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}}, \quad r = \frac{f}{f_n}, \quad \delta_{req} = \frac{g}{(2\pi f_{n,req})^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Disturbing (running) frequency | 1/s |
| \(f_n\) | Mounted natural frequency | 1/s |
| \(\zeta\) | Damping ratio | - |
| \(\eta_t\) | Target isolation efficiency | - |
| \(r\) | Frequency ratio f/f_n | - |
| \(TR\) | Transmissibility | - |
| \(\eta\) | Isolation efficiency | - |
| \(f_{n,req}\) | Natural frequency for the target (undamped) | 1/s |
| \(\delta_{req}\) | Static deflection for the target | m |
Method and standards
Single-degree-of-freedom base isolation.
Where it is used
- Pump, fan and compressor mounts.
- Sensitive equipment isolation.
Common mistakes
- Selecting by load only, not deflection.
- Forgetting start-up resonance.
Assumptions and limits
The required natural frequency and static deflection are for an undamped, linear mount: δ = g/(2πf_n)² holds only for mounts whose deflection is proportional to load (steel springs, not rubber in its stiffening range). Damping raises the transmissibility above √2, so allow some margin.
At exact resonance with zero damping the transmissibility is unbounded and not shown.
Single degree of freedom; vertical mode.
References
- Rao
- Mechanical Vibrations
- 6th ed. (Pearson, 2017)
- ch. 3 (force transmissibility)
Questions and answers
When do mounts start to isolate?
Above a frequency ratio of √2; below it they amplify, worst at resonance.
Why does damping hurt isolation?
Above √2, damping raises transmissibility; it is still useful to limit resonance during start-up.
What do the defaults represent?
A 1,480 rpm machine on mounts with a 5 Hz natural frequency and light damping.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.