FireCADCalc

Vibration Isolation: Transmissibility and Isolator Deflection

Force transmissibility and isolation efficiency of a mounted machine from running speed, mount natural frequency and damping, and deflection needed.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 1,480 rpm on 5 Hz mounts, ζ 0.05960 rpm on 12 Hz pads, ζ 0.1

Results

Frequency ratio f/f_n4.9333
Transmissibility0.047769
Isolation efficiency95.223%
Natural frequency for the target (undamped)7.4373Hz
Static deflection for the target4.4909mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1,480 rpm on 5 Hz mounts, ζ 0.05. The inputs, in the units selected above:

InputValue
Disturbing (running) frequency1,480.0 rpm
Mounted natural frequency5.0000 Hz
Damping ratio5.0000 %
Target isolation efficiency90.000 %

Applying the formula below gives:

ResultValue
Frequency ratio f/f_n4.9333
Transmissibility0.047769
Isolation efficiency95.223 %
Natural frequency for the target (undamped)7.4373 Hz
Static deflection for the target4.4909 mm

Open this example in the calculator and change any input.

Formula

\(TR = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}}, \quad r = \frac{f}{f_n}, \quad \delta_{req} = \frac{g}{(2\pi f_{n,req})^2}\)

Variables

Symbol Meaning SI unit
\(N\) Disturbing (running) frequency 1/s
\(f_n\) Mounted natural frequency 1/s
\(\zeta\) Damping ratio -
\(\eta_t\) Target isolation efficiency -
\(r\) Frequency ratio f/f_n -
\(TR\) Transmissibility -
\(\eta\) Isolation efficiency -
\(f_{n,req}\) Natural frequency for the target (undamped) 1/s
\(\delta_{req}\) Static deflection for the target m

Method and standards

Single-degree-of-freedom base isolation.

Where it is used

  • Pump, fan and compressor mounts.
  • Sensitive equipment isolation.

Common mistakes

  • Selecting by load only, not deflection.
  • Forgetting start-up resonance.

Assumptions and limits

  • The required natural frequency and static deflection are for an undamped, linear mount: δ = g/(2πf_n)² holds only for mounts whose deflection is proportional to load (steel springs, not rubber in its stiffening range). Damping raises the transmissibility above √2, so allow some margin.

  • At exact resonance with zero damping the transmissibility is unbounded and not shown.

  • Single degree of freedom; vertical mode.

References

  • Rao
  • Mechanical Vibrations
  • 6th ed. (Pearson, 2017)
  • ch. 3 (force transmissibility)

Questions and answers

When do mounts start to isolate?

Above a frequency ratio of √2; below it they amplify, worst at resonance.

Why does damping hurt isolation?

Above √2, damping raises transmissibility; it is still useful to limit resonance during start-up.

What do the defaults represent?

A 1,480 rpm machine on mounts with a 5 Hz natural frequency and light damping.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.