FireCADCalc

Tuned Mass Damper: Optimum Tuning and Damping

Optimum frequency ratio, damping ratio, spring and dashpot of a tuned mass damper for a main mass and spring, with the resulting peak amplification.

Inputs

Examples: Illustrative 20 t structure, 5 % absorberFootbridge mode, 2 % absorberMachine frame, 10 % absorber

Accepted: 0.001 to 1E+9 kg
Accepted: 0.001 to 1E+9 kN/m
Accepted: 0.0001 to 100,000,000 kg

Results

A small mass on a spring and damper attached to a vibrating structure absorbs energy near the structure's resonance. Equal-peak (fixed-point) tuning for harmonic force on an undamped main system gives the absorber natural frequency ω_a = ω_n/(1 + μ) and damping ratio ζ = √[3μ/8(1 + μ)³], leaving a peak amplification of about √(1 + 2/μ) instead of an infinite resonance. Mass ratios of 1–10 % are typical; a larger absorber mass is more robust to mistuning. Building and bridge dampers are usually tuned to the measured frequency on site.

Natural frequency of the main system10.066Hz
Mass ratio m_a/M0.10000
Optimum frequency ratio ω_a/ω_n0.90909
Optimum absorber damping ratio0.16785
Absorber spring stiffness264.46kN/m
Absorber damping coefficient (N·s/m)1,544.1
Peak amplification of the main mass (equal-peak estimate)4.5826

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 t structure, 5 % absorber. The inputs, in the units selected above:

InputValue
Main (structure) mass20,000 kg
Main stiffness8,000.0 kN/m
Absorber mass1,000.0 kg

Applying the formula below gives:

ResultValue
Natural frequency of the main system3.1831 Hz
Mass ratio m_a/M0.050000
Optimum frequency ratio ω_a/ω_n0.95238
Optimum absorber damping ratio0.12727
Absorber spring stiffness362.81 kN/m
Absorber damping coefficient (N·s/m)4,848.3
Peak amplification of the main mass (equal-peak estimate)6.4031

Open this example in the calculator and change any input.

Formula

\(\frac{\omega_a}{\omega_n} = \frac1{1+\mu}, \quad \zeta_{opt} = \sqrt{\frac{3\mu}{8(1+\mu)^3}}, \quad \frac{X}{X_{st}} \approx \sqrt{1 + \frac2\mu}\)

Variables

Symbol Meaning SI unit
\(M\) Main (structure) mass kg
\(K\) Main stiffness N/m
\(m_a\) Absorber mass kg
\(f_n\) Natural frequency of the main system 1/s
\(\mu\) Mass ratio m_a/M -
\(f_{opt}\) Optimum frequency ratio ω_a/ω_n -
\(\zeta_{opt}\) Optimum absorber damping ratio -
\(k_a\) Absorber spring stiffness N/m
\(c_a\) Absorber damping coefficient (N·s/m) -
\(X/X_{st}\) Peak amplification of the main mass (equal-peak estimate) -

Method and standards

Tuned mass damper.

Where it is used

  • Footbridges, chimneys, buildings and machinery.
  • Retrofitting resonant structures.

Common mistakes

  • Tuning to the undamped structure without the absorber's mass effect.
  • Using too small a mass ratio.

Assumptions and limits

  • Undamped main system; harmonic force excitation; single mode.

References

  • Equal-peak optimum damped vibration absorber

Questions and answers

Why not tune the absorber exactly to the structure?

With damping, slightly lower tuning equalises the two resonance peaks and minimises the worst one.

What mass ratio is needed?

Usually 1–5 % for buildings and footbridges, more for machinery where space allows.

What do the defaults represent?

An illustrative 20 t structure with 8 MN/m stiffness (3.2 Hz) and a 1 t (5 %) absorber.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Den Hartog, Mechanical Vibrations, 4th ed. (McGraw-Hill, 1956)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.