Worked example
Example: Illustrative 20 t structure, 5 % absorber. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Main (structure) mass | 20,000 kg |
| Main stiffness | 8,000.0 kN/m |
| Absorber mass | 1,000.0 kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Natural frequency of the main system | 3.1831 Hz |
| Mass ratio m_a/M | 0.050000 |
| Optimum frequency ratio ω_a/ω_n | 0.95238 |
| Optimum absorber damping ratio | 0.12727 |
| Absorber spring stiffness | 362.81 kN/m |
| Absorber damping coefficient (N·s/m) | 4,848.3 |
| Peak amplification of the main mass (equal-peak estimate) | 6.4031 |
Open this example in the calculator and change any input.
Formula
\(\frac{\omega_a}{\omega_n} = \frac1{1+\mu}, \quad \zeta_{opt} = \sqrt{\frac{3\mu}{8(1+\mu)^3}}, \quad \frac{X}{X_{st}} \approx \sqrt{1 + \frac2\mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Main (structure) mass | kg |
| \(K\) | Main stiffness | N/m |
| \(m_a\) | Absorber mass | kg |
| \(f_n\) | Natural frequency of the main system | 1/s |
| \(\mu\) | Mass ratio m_a/M | - |
| \(f_{opt}\) | Optimum frequency ratio ω_a/ω_n | - |
| \(\zeta_{opt}\) | Optimum absorber damping ratio | - |
| \(k_a\) | Absorber spring stiffness | N/m |
| \(c_a\) | Absorber damping coefficient (N·s/m) | - |
| \(X/X_{st}\) | Peak amplification of the main mass (equal-peak estimate) | - |
Method and standards
Tuned mass damper.
Where it is used
- Footbridges, chimneys, buildings and machinery.
- Retrofitting resonant structures.
Common mistakes
- Tuning to the undamped structure without the absorber's mass effect.
- Using too small a mass ratio.
Assumptions and limits
- Undamped main system; harmonic force excitation; single mode.
References
- Equal-peak optimum damped vibration absorber
Questions and answers
Why not tune the absorber exactly to the structure?
With damping, slightly lower tuning equalises the two resonance peaks and minimises the worst one.
What mass ratio is needed?
Usually 1–5 % for buildings and footbridges, more for machinery where space allows.
What do the defaults represent?
An illustrative 20 t structure with 8 MN/m stiffness (3.2 Hz) and a 1 t (5 %) absorber.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Den Hartog, Mechanical Vibrations, 4th ed. (McGraw-Hill, 1956)