Worked example
Example: 10 → 4 mm over 5 cycles at 12 Hz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First peak amplitude | 10.000 mm |
| Peak amplitude n cycles later | 4.0000 mm |
| Cycles between the peaks | 5.0000 - |
| Measured damped frequency | 12.000 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Logarithmic decrement | 0.18326 |
| Damping ratio | 2.9154 % |
| Undamped natural frequency | 12.005 Hz |
| Quality factor 1/(2ζ) | 17.150 |
Open this example in the calculator and change any input.
Formula
\(\delta = \frac1n\ln\frac{x_1}{x_{n+1}}, \quad \zeta = \frac{\delta}{\sqrt{4\pi^2 + \delta^2}}, \quad f_n = \frac{f_d}{\sqrt{1 - \zeta^2}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | First peak amplitude | m |
| \(x_{n+1}\) | Peak amplitude n cycles later | m |
| \(n\) | Cycles between the peaks | - |
| \(f_d\) | Measured damped frequency | 1/s |
| \(\delta\) | Logarithmic decrement | - |
| \(\zeta\) | Damping ratio | - |
| \(f_n\) | Undamped natural frequency | 1/s |
| \(Q\) | Quality factor 1/(2ζ) | - |
Method and standards
Viscous damping decay.
Where it is used
- Bump tests of foundations and pipework.
- Checking mount damping.
Common mistakes
- Using peaks of opposite sign.
- Mixing displacement and acceleration peaks over changing frequency.
Assumptions and limits
- Viscous damping; single mode.
References
- Rao
- Mechanical Vibrations
- 6th ed. (Pearson, 2017)
- ch. 2 (logarithmic decrement)
Questions and answers
Why measure over several cycles?
Lightly damped systems lose little per cycle; measuring over n cycles improves accuracy.
What damping is typical?
Steel structures 1–2 %, bolted structures 2–5 %, rubber mounts 5–10 %.
What do the defaults represent?
A decay from 10 to 4 mm over 5 cycles at 12 Hz.