FireCADCalc

Silo Wall Pressure by Janssen's Equation

Vertical and wall pressure in a silo at a depth by Janssen's equation from bulk density, wall friction, pressure ratio and diameter, with the deep-silo limit.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 8 m coal silo at 20 mCement silo 5 m at 30 m

Results

Janssen gives filling (static) pressures. Discharge can raise wall pressure by 1.5–2.5 times locally; structural design uses the governing silo code's overpressure factors.

Vertical pressure at depth z70.506kPa
Wall (horizontal) pressure35.253kPa
Wall friction stress15.864kPa
Asymptotic wall pressure (deep silo)35.413kPa
Hydrostatic pressure for comparison382.46kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 m coal silo at 20 m. The inputs, in the units selected above:

InputValue
Silo diameter8.0000 m
Depth below the material surface20.000 m
Bulk density800.00 kg/m³
Wall friction coefficient0.40000 -
Horizontal-to-vertical pressure ratio0.45000 -

Applying the formula below gives:

ResultValue
Vertical pressure at depth z72.761 kPa
Wall (horizontal) pressure32.742 kPa
Wall friction stress13.097 kPa
Asymptotic wall pressure (deep silo)39.227 kPa
Hydrostatic pressure for comparison156.91 kPa

Open this example in the calculator and change any input.

Formula

\(p_v = \frac{\rho gR_h}{\mu_wK}\left(1 - e^{-\mu_wKz/R_h}\right), \quad R_h = \frac{D}{4}, \quad p_h = Kp_v\)

Variables

Symbol Meaning SI unit
\(D\) Silo diameter m
\(z\) Depth below the material surface m
\(\rho_b\) Bulk density kg/m³
\(\mu_w\) Wall friction coefficient -
\(K\) Horizontal-to-vertical pressure ratio -
\(p_v\) Vertical pressure at depth z Pa
\(p_h\) Wall (horizontal) pressure Pa
\(\tau_w\) Wall friction stress Pa
\(p_{h,\infty}\) Asymptotic wall pressure (deep silo) Pa
\(\rho gz\) Hydrostatic pressure for comparison Pa

Method and standards

Janssen's equation.

Where it is used

  • Silo and bunker checks.
  • Explaining why deep silos do not crush their contents.

Common mistakes

  • Using fluid hydrostatics for solids.
  • Ignoring discharge overpressure.

Assumptions and limits

  • Static filling; uniform material.

References

  • Janssen (1895) equation
  • as given in Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 21 (storage of solids)

Questions and answers

Why does silo pressure stop growing with depth?

Wall friction carries part of the weight; below about three diameters the pressure approaches a constant, unlike a liquid.

What value of K?

About 0.4–0.5 for free-flowing solids; 1 − sin φ (Jaky) is a common estimate.

What do the defaults represent?

An 8 m coal silo at 20 m depth.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.