Worked example
Example: 3 t at 500 mm, load at 800 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rated capacity | 3,000.0 kg |
| Rated load centre | 500.00 mm |
| Actual load centre | 800.00 mm |
| Front axle to fork face distance | 450.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capacity at the actual load centre | 2,280.0 kg |
| Derating | 76.000 % |
Open this example in the calculator and change any input.
Formula
\(Q = \min\left(Q_r,\ Q_r\frac{a + c_r}{a + c}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q_r\) | Rated capacity | kg |
| \(c_r\) | Rated load centre | m |
| \(c\) | Actual load centre | m |
| \(a\) | Front axle to fork face distance | m |
| \(Q\) | Capacity at the actual load centre | kg |
| \(Q/Q_r\) | Derating | - |
Method and standards
Moment balance.
Where it is used
- Handling long or bulky loads.
- Choosing a truck size.
Common mistakes
- Measuring the load centre from the heel of the forks only.
- Ignoring attachments.
Assumptions and limits
- Rigid truck on level ground. A load centre shorter than rated does not raise the capacity above Q_r.
References
- Moment balance about the front axle (definitions)
Questions and answers
Why does capacity fall with load centre?
The truck's counterweight provides a fixed resisting moment about the front wheels; a load further out uses it up faster.
Is the plate value always lower?
Often yes, at full mast height; the plate governs.
What do the defaults represent?
A 3 t forklift rated at a 500 mm load centre carrying a load centred at 800 mm.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.