Worked example
Example: 3 mm granules, 300 mm round outlet. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Outlet shape | Circular |
| Outlet diameter or slot width | 300.00 mm |
| Particle size | 3.0000 mm |
| Bulk density | 800.00 kg/m³ |
| Beverloo constant | 0.58000 - |
| Particle shape constant | 1.4000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Discharge rate (per metre of slot length for a slot) | 248.93 t/h |
| Effective outlet size | 295.80 mm |
Open this example in the calculator and change any input.
Formula
\(W = C\rho_b\sqrt g\,(D_0 - kd_p)^{2.5}\ \text{(circular)}, \quad W_s = 1.03\,C\rho_b\sqrt g\,(D_0 - kd_p)^{1.5}\ \text{(slot, per metre of length)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{outlet}\) | Outlet shape | - |
| \(D_0\) | Outlet diameter or slot width | m |
| \(d_p\) | Particle size | m |
| \(\rho_b\) | Bulk density | kg/m³ |
| \(C\) | Beverloo constant | - |
| \(k\) | Particle shape constant | - |
| \(W\) | Discharge rate (circular outlet) | kg/s |
| \(W_s\) | Discharge rate per metre of slot length (slot outlet) | kg/(s·m) |
| \(D_0 - kd_p\) | Effective outlet size | m |
Method and standards
Beverloo correlation.
Where it is used
- Feeder and gate sizing.
- Checking a bunker outlet for a required rate.
Common mistakes
- Using it for fine or cohesive powders.
- Outlet smaller than the arching dimension.
Assumptions and limits
- Coarse free-flowing solids; particles below about 0.5 mm are flagged.
- For a slot outlet (width entered as D₀) the result W_s is per metre of slot length. The slot coefficient 1.03 is carried from the earlier FireCAD version; its printed source is not yet confirmed, so treat the slot result as an estimate.
References
- Beverloo
- Leniger and van de Velde (1961)
- Chem. Eng. Sci. 15: 260; Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 21
Questions and answers
Why doesn't discharge depend on fill height?
Unlike a liquid, a granular solid's outlet flow is set by the arch region just above the outlet; the head above is carried by the walls.
What is the 'empty annulus' k·d_p?
Particles near the edge of the outlet do not fall freely; the effective opening is reduced by about 1.4 particle diameters.
What do the defaults represent?
Free-flowing 3 mm granules through a 300 mm round outlet.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.