Worked example
Example: 8 m coal silo at 20 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Silo diameter | 8.0000 m |
| Depth below the material surface | 20.000 m |
| Bulk density | 800.00 kg/m³ |
| Wall friction coefficient | 0.40000 - |
| Horizontal-to-vertical pressure ratio | 0.45000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vertical pressure at depth z | 72.761 kPa |
| Wall (horizontal) pressure | 32.742 kPa |
| Wall friction stress | 13.097 kPa |
| Asymptotic wall pressure (deep silo) | 39.227 kPa |
| Hydrostatic pressure for comparison | 156.91 kPa |
Open this example in the calculator and change any input.
Formula
\(p_v = \frac{\rho gR_h}{\mu_wK}\left(1 - e^{-\mu_wKz/R_h}\right), \quad R_h = \frac{D}{4}, \quad p_h = Kp_v\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Silo diameter | m |
| \(z\) | Depth below the material surface | m |
| \(\rho_b\) | Bulk density | kg/m³ |
| \(\mu_w\) | Wall friction coefficient | - |
| \(K\) | Horizontal-to-vertical pressure ratio | - |
| \(p_v\) | Vertical pressure at depth z | Pa |
| \(p_h\) | Wall (horizontal) pressure | Pa |
| \(\tau_w\) | Wall friction stress | Pa |
| \(p_{h,\infty}\) | Asymptotic wall pressure (deep silo) | Pa |
| \(\rho gz\) | Hydrostatic pressure for comparison | Pa |
Method and standards
Janssen's equation.
Where it is used
- Silo and bunker checks.
- Explaining why deep silos do not crush their contents.
Common mistakes
- Using fluid hydrostatics for solids.
- Ignoring discharge overpressure.
Assumptions and limits
- Static filling; uniform material.
References
- Janssen (1895) equation
- as given in Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 21 (storage of solids)
Questions and answers
Why does silo pressure stop growing with depth?
Wall friction carries part of the weight; below about three diameters the pressure approaches a constant, unlike a liquid.
What value of K?
About 0.4–0.5 for free-flowing solids; 1 − sin φ (Jaky) is a common estimate.
What do the defaults represent?
An 8 m coal silo at 20 m depth.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.