FireCADCalc

Silo and Hopper Volume and Capacity

Volume and capacity of a round silo or bunker with a conical hopper bottom and a heaped top, from diameter, heights, hopper angle and bulk density.

Thermal power plantSugar mill and cogenerationBoilerTank and drum

Inputs

Examples: Coal bunker 4 m dia, 6 m straight, 60° hopper to 300 mm, 800 kg/m³Fly ash silo 8 m, 12 m, 60° to 400 mm, 750 kg/m³Biomass silo 6 m, 8 m, 70° to 600 mm, heaped at 35°, 250 kg/m³

Results

Geometric volume: the usable capacity is less where material hangs up, rat-holes or cannot be heaped to the top.

Height of the hopper cone7.4182m
Volume of the hopper77.605m³
Volume of the cylindrical part226.19m³
Volume of the heaped top19.798m³
Total volume323.60m³
Capacity at the bulk density80.899t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal bunker 4 m dia, 6 m straight, 60° hopper to 300 mm, 800 kg/m³. The inputs, in the units selected above:

InputValue
Silo diameter4.0000 m
Height of the cylindrical part6.0000 m
Hopper outlet diameter300.00 mm
Hopper wall angle from horizontal60.000 °
Angle of repose of the heaped top (0 = level)0 °
Bulk density of the material800.00 kg/m³

Applying the formula below gives:

ResultValue
Height of the hopper cone3.2043 m
Volume of the hopper14.504 m³
Volume of the cylindrical part75.398 m³
Volume of the heaped top0 m³
Total volume89.902 m³
Capacity at the bulk density71.922 t

Open this example in the calculator and change any input.

Formula

\(h_c = \frac{D - d}{2} \tan\theta, \quad V_c = \frac{\pi h_c}{12} (D^2 + D d + d^2)\)

\(V_s = \frac{\pi}{4} D^2 H, \quad V_t = \frac{\pi D^2}{12} \cdot \frac{D}{2} \tan\phi\)

\(V = V_c + V_s + V_t, \quad W = V \rho_b\)

Variables

Symbol Meaning SI unit
\(D\) silo diameter m
\(H\) height of the cylinder m
\(d\) outlet diameter m
\(\theta\) hopper wall angle from horizontal rad
\(\phi\) angle of repose of the heaped top rad
\(\rho_b\) bulk density kg/m³
\(h_c\) hopper height m
\(V_c\) hopper volume m³
\(V_s\) cylinder volume m³
\(V_t\) heaped top volume m³
\(V\) total volume m³
\(W\) capacity kg

Method and standards

The hopper is a frustum of a cone from the silo diameter to the outlet; the heaped top is a cone at the angle of repose. Capacity is total volume times bulk density.

Where it is used

  • Sizing coal, ash, limestone and biomass silos.
  • Converting a level reading to stored tonnes.
  • Comparing bunker designs.

Common mistakes

  • Using particle density instead of bulk density.
  • Taking the hopper angle from vertical instead of horizontal.
  • Counting volume above the inlet that never fills.

Assumptions and limits

  • Round silo with a single central conical outlet.
  • Geometric volume; hang-ups and dead zones reduce live capacity.

References

  • Geometry of cylinder
  • frustum and cone

Questions and answers

How much does a 4 m silo with 6 m straight and a 60° hopper hold?

About 90 m³: 75 m³ in the cylinder and 14.5 m³ in the hopper, about 72 t of coal at 800 kg/m³.

What hopper angle should I use?

Steep enough for mass flow of the material; 60° or steeper from horizontal is common for coal and ash, but cohesive materials need a flow test.

Is the heaped top usable?

Only if the filling point is central and the roof allows it; take 0 for a level fill.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.