FireCADCalc

Martensite Fraction on Quenching (Koistinen–Marburger)

Martensite fraction and retained austenite after quenching steel to a temperature below Ms, and the temperatures for 90 % and 99 % martensite.

Inputs

Examples: Illustrative steel, Ms 350 C to 20 CHigh-carbon steel, Ms 180 C to 20 CSub-zero treatment to -80 C

Accepted: -173.15 to 726.85 °C
Accepted: -269.15 to 726.85 °C
Accepted: 0.0001 to 0.1

Results

Martensite forms athermally: the fraction depends on how far below M_s the steel is cooled, not on time. Koistinen and Marburger fitted f_m = 1 − exp[−α(M_s − T_q)] with α = 0.011/K for plain carbon and low-alloy steels (any austenite that does not become bainite or ferrite first). High-carbon and high-alloy steels with low M_s retain austenite at room temperature, which a sub-zero treatment converts. Use M_s from the Andrews calculator.

Martensite fraction82.796%
Retained austenite17.204%
Temperature for 90 % martensite-29.326°C
Temperature for 99 % martensite-238.65°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative steel, Ms 350 C to 20 C. The inputs, in the units selected above:

InputValue
Martensite start temperature350.00 °C
Quench (lowest) temperature20.000 °C
Rate constant (1/K)0.011000 -

Applying the formula below gives:

ResultValue
Martensite fraction97.348 %
Retained austenite2.6516 %
Temperature for 90 % martensite140.67 °C
Temperature for 99 % martensite-68.652 °C

Open this example in the calculator and change any input.

Formula

\(f_m = 1 - e^{-\alpha_m(M_s - T_q)}, \quad T_{90} = M_s - \frac{\ln 10}{\alpha_m}\)

Variables

Symbol Meaning SI unit
\(M_s\) Martensite start temperature K
\(T_q\) Quench (lowest) temperature K
\(\alpha_m\) Rate constant (1/K) -
\(f_m\) Martensite fraction -
\(f_\gamma\) Retained austenite -
\(T_{90}\) Temperature for 90 % martensite K
\(T_{99}\) Temperature for 99 % martensite K

Method and standards

Martensite fraction.

Where it is used

  • Choosing sub-zero treatment for tool and bearing steels.
  • Heat treatment simulation inputs.

Common mistakes

  • Using it above M_s or for steels that form bainite first.
  • Taking α as universal for high-alloy steels.

Assumptions and limits

  • Fully austenitised steel; no prior bainite or ferrite; athermal kinetics.

References

  • Koistinen–Marburger relation

Questions and answers

Why does high-carbon steel keep austenite after quenching?

Its M_s is low, so room temperature is not far enough below it to transform everything.

Does holding at the quench temperature form more martensite?

Not appreciably: the transformation depends on undercooling, not time.

What do the defaults represent?

An illustrative steel with M_s = 350 °C quenched to 20 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Koistinen and Marburger, A General Equation Prescribing the Extent of the Austenite-Martensite Transformation, Acta Metallurgica 7 (1959)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...