FireCADCalc

Furnace Heating Time to Temperature and Soak (One-Term Solution)

Time for the centre of a plate or bar in a furnace to come within a set margin of furnace temperature, with radiation and convection, plus the soak time.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative 100 mm bar to 850 CPlate 60 mm normalised at 900 CStress relief of 200 mm bar at 620 C

Accepted: 2 to 1,000 mm
Accepted: 5 to 400 W/(m·K)
Accepted: 1,000 to 20,000 kg/m³
Accepted: 0.1 to 2 kJ/(kg·K)
Accepted: -23.15 to 1,226.8 °C
Accepted: 26.85 to 1,426.8 °C
Accepted: 1 to 200 K
Accepted: 0 to 500 W/(m²·K)
Accepted: 0 to 100 %
Accepted: 0 to 1,666.7 min

Results

h = h_c + εσ(T_f² + T_s²)(T_f + T_s) with T_s midway between furnace and target. One-term solution: centre θ = C₁e^(−λ₁²Fo); accurate for Fo above about 0.2. Real heating is faster at first (radiation scales with T⁴) and properties vary; furnace load and spacing matter as much as section size. Soak time is the metallurgical hold, from the procedure.

Combined surface coefficient328.31W/(m²·K)
Biot number0.32831
Fourier number at the end of heating13.949
Heating time33.944min
Heating plus soak53.944min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 mm bar to 850 C. The inputs, in the units selected above:

InputValue
Section shapeLong round bar
Half-thickness or radius50.000 mm
Thermal conductivity30.000 W/(m·K)
Density7,850.0 kg/m³
Specific heat (mean)0.60000 kJ/(kg·K)
Initial temperature30.000 °C
Furnace temperature850.00 °C
Allowed centre lag behind furnace10.000 K
Convective coefficient15.000 W/(m²·K)
Surface emissivity80.000 %
Metallurgical soak time at temperature30.000 min

Applying the formula below gives:

ResultValue
Combined surface coefficient270.37 W/(m²·K)
Biot number0.45062
Fourier number at the end of heating5.5825
Heating time36.519 min
Heating plus soak66.519 min

Open this example in the calculator and change any input.

Formula

\(\frac{T_f - T_c}{T_f - T_i} = C_1e^{-\lambda_1^2Fo}, \quad t_h = \frac{Fo\,L^2\rho c_p}{k}, \quad h = h_c + \varepsilon\sigma(T_f^2 + T_s^2)(T_f + T_s)\)

Variables

Symbol Meaning SI unit
\(\text{shape}\) Section shape -
\(L\) Half-thickness or radius m
\(k\) Thermal conductivity W/(m·K)
\(\rho\) Density kg/m³
\(c_p\) Specific heat (mean) J/(kg·K)
\(T_i\) Initial temperature K
\(T_f\) Furnace temperature K
\(\Delta T_c\) Allowed centre lag behind furnace K
\(h_c\) Convective coefficient W/(m²·K)
\(\varepsilon\) Surface emissivity -
\(t_s\) Metallurgical soak time at temperature s
\(h\) Combined surface coefficient W/(m²·K)
\(Bi\) Biot number -
\(Fo\) Fourier number at the end of heating -
\(t_h\) Heating time s
\(t\) Heating plus soak s

Method and standards

Heating time.

Where it is used

  • Planning hardening, normalising and stress-relief cycles.
  • Furnace loading schedules.

Common mistakes

  • Starting soak timing when the furnace, not the part, reaches temperature.
  • Ignoring shading of parts in dense loads.

Assumptions and limits

  • Constant properties and h; isolated part; one-term solution.

References

  • One-term transient conduction with linearised radiation

Questions and answers

Why not just use one hour per inch?

The rule ignores furnace temperature, emissivity and material; this calculation shows where it is generous or short.

What is the soak time for?

Time at temperature for the metallurgical change itself, such as dissolving carbides before hardening, after the centre has arrived.

What do the defaults represent?

An illustrative 100 mm steel bar heated from 30 °C in an 850 °C furnace to within 10 K at the centre, emissivity 0.8, h_c 15, then soaked 30 minutes.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, 6th ed. (Wiley, 2007), Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.