FireCADCalc

Reliability and Availability: MTBF, MTTR, Series and Parallel

Availability of one item from MTBF and MTTR, the availability of n identical items in series and in parallel (redundant), and the reliability over a mission time.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 50,000 h MTBF, 8 h MTTR, two units, one yearPump 8,000 h, 24 h repair, three units

Results

Constant failure rate (exponential) and independent failures; common-cause failures limit the real benefit of redundancy.

Availability of one item99.701%
Availability, n in series99.105%
Availability, n in parallel (1 needed)100.000%
Reliability of one item over the mission57.839%
Expected downtime per year, one item26.201h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50,000 h MTBF, 8 h MTTR, two units, one year. The inputs, in the units selected above:

InputValue
Mean time between failures50,000 h
Mean time to repair8.0000 h
Number of identical items2.0000 -
Mission time8,760.0 h

Applying the formula below gives:

ResultValue
Availability of one item99.984 %
Availability, n in series99.968 %
Availability, n in parallel (1 needed)100.000 %
Reliability of one item over the mission83.929 %
Expected downtime per year, one item1.4014 h

Open this example in the calculator and change any input.

Formula

\(A = \frac{MTBF}{MTBF + MTTR}, \quad A_s = A^n, \quad A_p = 1 - (1 - A)^n, \quad R(t) = e^{-t/MTBF}\)

Variables

Symbol Meaning SI unit
\(MTBF\) Mean time between failures s
\(MTTR\) Mean time to repair s
\(n\) Number of identical items -
\(t\) Mission time s
\(A\) Availability of one item -
\(A_s\) Availability, n in series -
\(A_p\) Availability, n in parallel (1 needed) -
\(R(t)\) Reliability of one item over the mission -
\(D\) Expected downtime per year, one item s

Method and standards

Constant-failure-rate reliability.

Where it is used

  • Pump and fan redundancy decisions.
  • Instrument system availability.

Common mistakes

  • Ignoring common-cause failures.
  • Using MTBF for wear-out items.

Assumptions and limits

  • Independent, constant failure rates.
  • The number of items is a whole number; a fractional entry is rounded, with a note.

References

  • Reliability mathematics with constant failure rates (definitions; O'Connor, Practical Reliability Engineering)

Questions and answers

Why does redundancy help so much?

With two pumps each 99 % available, both are down at once only 0.01 % of the time.

Why does series hurt?

Every item must work; ten items each 99 % available give only 90 %.

What do the defaults represent?

Items with 50,000 h MTBF and 8 h repair, two in parallel, over one year.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.