Worked example
Example: Saturation temperature at 11 bar from 10 and 12 bar rows. The inputs, in the units selected above:
| Input | Value |
|---|---|
| First known x | 10.000 - |
| y at x₁ | 179.88 - |
| Second known x | 12.000 - |
| y at x₂ | 187.96 - |
| x to interpolate at | 11.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Interpolated value | 183.92 |
| Slope (y₂ − y₁) / (x₂ − x₁) | 4.0400 |
| Position between the points (x − x₁) / (x₂ − x₁) | 0.50000 |
Open this example in the calculator and change any input.
Formula
\(y = y_1 + (x - x_1)\, \frac{y_2 - y_1}{x_2 - x_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_1\) | First known x | - |
| \(y_1\) | y at x₁ | - |
| \(x_2\) | Second known x | - |
| \(y_2\) | y at x₂ | - |
| \(x\) | x to interpolate at | - |
| \(y\) | Interpolated value | - |
| \(m\) | Slope (y₂ − y₁) / (x₂ − x₁) | - |
| \(f\) | Position between the points (x − x₁) / (x₂ − x₁) | - |
Method and standards
Straight line through two points.
Where it is used
- Boiler attendant examinations: steam table values between rows.
- Reading any engineering table.
- Data sheets.
Common mistakes
- Swapping x and y.
- Interpolating across a phase change.
- Extrapolating far beyond the table.
Assumptions and limits
- Straight line between the two points.
References
- Linear (Lagrange first-order) interpolation
Questions and answers
What is the saturation temperature at 11 bar from rows at 10 bar (179.88 °C) and 12 bar (187.96 °C)?
183.92 °C: halfway between the rows.
Is linear interpolation accurate in steam tables?
Between close rows, yes; across wide gaps the curve bends and the error grows.
What is extrapolation?
Going beyond the two points. The calculator warns, because the straight line may not hold there.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.