FireCADCalc

Crop Irrigation Water Requirement and Pump Flow

Net and gross irrigation requirement of a crop from reference evapotranspiration, crop coefficient and effective rainfall, and the volume and pump flow for an area.

Inputs

Examples: Illustrative 10 ha crop at peakWheat, winterRainy period

Accepted: 0 to 20
Accepted: 0.1 to 1.5
Accepted: 0 to 50
Accepted: 30 to 100 %
Accepted: 30 to 100 %
Accepted: 0.0001 to 100,000 ha
Accepted: 1 to 24 h

Results

Crop water use ET_c = K_c ET₀ is partly met by effective rainfall; the rest is the net irrigation requirement. Losses in canals or pipes (conveyance) and in the field (application) raise it to the gross requirement, which sets the water volume and, for the pumping hours available, the pump flow. Use the peak month for system capacity.

Crop evapotranspiration (mm per day)5.7750
Net irrigation requirement (mm per day)5.2750
Gross irrigation requirement (mm per day)8.3730
Water volume per day837.30m³
Pump flow23.258L/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 ha crop at peak. The inputs, in the units selected above:

InputValue
Reference evapotranspiration (mm per day)5.5000 -
Crop coefficient1.0500 -
Effective rainfall (mm per day)0.50000 -
Conveyance efficiency90.000 %
Application efficiency70.000 %
Irrigated area10.000 ha
Pumping hours per day10.000 h

Applying the formula below gives:

ResultValue
Crop evapotranspiration (mm per day)5.7750
Net irrigation requirement (mm per day)5.2750
Gross irrigation requirement (mm per day)8.3730
Water volume per day837.30 m³
Pump flow23.258 L/s

Open this example in the calculator and change any input.

Formula

\(ET_c = K_c ET_0, \quad NIR = ET_c - P_e, \quad GIR = \frac{NIR}{\eta_c\eta_a}, \quad Q = \frac{GIR\,A}{t_p}\)

Variables

Symbol Meaning SI unit
\(ET_0\) Reference evapotranspiration (mm per day) -
\(K_c\) Crop coefficient -
\(P_e\) Effective rainfall (mm per day) -
\(\eta_c\) Conveyance efficiency -
\(\eta_a\) Application efficiency -
\(A\) Irrigated area m²
\(t_p\) Pumping hours per day s
\(ET_c\) Crop evapotranspiration (mm per day) -
\(NIR\) Net irrigation requirement (mm per day) -
\(GIR\) Gross irrigation requirement (mm per day) -
\(V\) Water volume per day m³
\(Q\) Pump flow m³/s

Method and standards

Irrigation requirement.

Where it is used

  • Irrigation system capacity.
  • Canal and pump planning.

Common mistakes

  • Using annual averages for peak capacity.
  • Counting all rainfall as effective.

Assumptions and limits

  • Daily averages for the period.

Questions and answers

How much water does 10 ha of sugarcane need in summer?

At ET₀ 5.5 mm/day and K_c 1.05 with 63 % overall efficiency, about 840 m³ a day.

What is effective rainfall?

The part of rain stored in the root zone; heavy showers run off and light ones evaporate.

What do the defaults represent?

An illustrative 10 ha crop at peak with ET₀ 5.5 mm/day, K_c 1.05, 0.5 mm/day effective rain and 90 % conveyance and 70 % application efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Allen, Pereira, Raes and Smith, Crop Evapotranspiration, FAO Irrigation and Drainage Paper 56 (FAO, 1998), Doorenbos and Pruitt, Crop Water Requirements, FAO Irrigation and Drainage Paper 24 (FAO, 1977)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.