Greenhouse Fan-and-Pad Evaporative Cooling

Air leaving an evaporative pad, the air flow to hold a temperature rise across a greenhouse, the pad area and the number of fans.

Inputs

Examples: Illustrative 1000 m2 greenhouseDry climate, large houseHumid, small house

Accepted: 1 to 1,000,000 m²
Accepted: 0.01 to 1.5 kW/m²
Accepted: 10 to 50 °C
Accepted: 0 to 40 °C
Accepted: 30 to 100 %
Accepted: 1 to 15 K
Accepted: 0.3 to 3 m/s
Accepted: 360 to 108,000 m³/h

Results

Air drawn through a wetted pad cools towards the wet-bulb temperature: T_p = T_db − ε(T_db − T_wb), with ε about 0.75–0.85 for 100–150 mm cellulose pads. Crossing the house it picks up the solar and other heat, so the air flow must be large enough to limit that rise: Q/(ρ c_p ΔT). The pad area is the flow over the face velocity (about 1.25 m/s for 100 mm pads). Fan-and-pad cooling works best in dry climates with a large wet-bulb depression.

Air temperature leaving the pad28.500°C
Air temperature at the fans31.500°C
Air flow needed178,388m³/h
Pad area49.552m²
Fans needed9.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1000 m2 greenhouse. The inputs, in the units selected above:

InputValue
Floor area1,000.0 m²
Heat gain per floor area (solar and other)0.40000 kW/m²
Outside dry-bulb temperature38.000 °C
Outside wet-bulb temperature24.000 °C
Pad saturation efficiency80.000 %
Allowed temperature rise from pad to fans4.0000 K
Pad face velocity1.2500 m/s
Capacity of one fan35,000 m³/h

Applying the formula below gives:

ResultValue
Air temperature leaving the pad26.800 °C
Air temperature at the fans30.800 °C
Air flow needed304,085 m³/h
Pad area67.574 m²
Fans needed9.0000

Open this example in the calculator and change any input.

Formula

\(T_p = T_{db} - \varepsilon(T_{db} - T_{wb}), \quad \dot V = \frac{q_s A_f}{\rho c_p \Delta T}, \quad A_p = \frac{\dot V}{v_p}\)

Variables

Symbol Meaning SI unit
\(A_f\) Floor area m²
\(q_s\) Heat gain per floor area (solar and other) W/m²
\(T_{db}\) Outside dry-bulb temperature K
\(T_{wb}\) Outside wet-bulb temperature K
\(\varepsilon\) Pad saturation efficiency -
\(\Delta T\) Allowed temperature rise from pad to fans K
\(v_p\) Pad face velocity m/s
\(\dot V_f\) Capacity of one fan m³/s
\(T_p\) Air temperature leaving the pad K
\(T_x\) Air temperature at the fans K
\(\dot V\) Air flow needed m³/s
\(A_p\) Pad area m²
\(n\) Fans needed -

Method and standards

Pad cooling.

Where it is used

  • Greenhouses, polyhouses and poultry houses.
  • Retrofitting cooling to existing houses.

Common mistakes

  • Designing for the dry-bulb temperature alone.
  • Pad velocity too high (water carry-over).

Assumptions and limits

  • Uniform pad wetting; steady conditions.

References

  • Greenhouse heat balance: cover conduction and air leakage

Questions and answers

How much pad does a 1,000 m² greenhouse need?

With 400 W/m² of heat gain and a 4 K rise, about 70 m² of 100 mm pad.

Why does it work poorly in humid weather?

The air can only cool to near its wet-bulb temperature, which is close to the dry bulb when humid.

What do the defaults represent?

An illustrative 1,000 m² greenhouse with 400 W/m² heat gain, outside 38 °C dry bulb and 24 °C wet bulb, 80 % pad, 4 K rise, 35,000 m³/h fans.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.