Worked example
Example: Illustrative 120-day crop. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Base period | 120.00 d |
| Duty (hectares per m³/s) | 1,800.0 - |
| Area to irrigate | 5,000.0 ha |
Applying the formula below gives:
| Result | Value |
|---|---|
| Delta | 576.00 mm |
| Discharge needed at the field | 2.7778 m³/s |
| Water over the base period | 2.8800e+07 m³ |
Open this example in the calculator and change any input.
Formula
\(\Delta = \frac{8.64\,B}{D}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(B\) | Base period | s |
| \(D\) | Duty (hectares per m³/s) | - |
| \(A\) | Area to irrigate | m² |
| \(\Delta\) | Delta | m |
| \(Q\) | Discharge needed at the field | m³/s |
| \(V\) | Water over the base period | m³ |
Method and standards
Duty and delta.
Where it is used
- Canal irrigation planning.
- Civil engineering examinations.
Common mistakes
- Mixing base period and crop period.
- Forgetting where the duty is measured.
Assumptions and limits
- Continuous flow over the base period.
References
- Classical irrigation engineering relations (duty and delta, Bligh and Lane creep, Khosla exit gradient)
Questions and answers
What delta corresponds to a duty of 1,800 ha/cumec over 120 days?
0.576 m.
What discharge does 5,000 ha need?
About 2.78 m³/s at the field.
What do the defaults represent?
An illustrative crop with a 120-day base period and a duty of 1,800 ha per cumec, for 5,000 ha.