FireCADCalc

Drip or Sprinkler Lateral Friction Loss (Christiansen Factor)

Friction loss along a drip or sprinkler lateral with many equally spaced outlets, from the full-flow Hazen–Williams loss and Christiansen's factor.

Inputs

Examples: Illustrative 100 m drip lateralLong 16 mm lateralSprinkler lateral, 10 outlets

Accepted: 1 to 2,000 m
Accepted: 0.1 to 50 m
Accepted: 0.1 to 10,000
Accepted: 5 to 200 mm
Accepted: 80 to 160
Accepted: 1 to 100 m

Results

Flow in a lateral falls as each outlet takes its share, so friction is much less than if the full flow ran the whole length. Christiansen's factor F = 1/(m+1) + 1/(2N) + √(m−1)/(6N²), with m = 1.852 for Hazen–Williams, scales the full-flow loss; for many outlets it approaches 0.35. Keep the lateral loss within about 20 % of the operating head (10 % flow variation for typical emitters), or use a larger pipe or feed from the middle.

Number of outlets375.00
Inlet flow750.00L/h
Christiansen factor0.35197
Friction loss along the lateral9.1729m
Loss as a share of the operating head91.729%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 m drip lateral. The inputs, in the units selected above:

InputValue
Lateral length100.00 m
Outlet (emitter) spacing0.60000 m
Flow per outlet (litres per hour)2.0000 -
Lateral inside diameter13.800 mm
Hazen–Williams coefficient150.00 -
Operating pressure head at the inlet10.000 m

Applying the formula below gives:

ResultValue
Number of outlets166.00
Inlet flow332.00 L/h
Christiansen factor0.35365
Friction loss along the lateral1.3584 m
Loss as a share of the operating head13.584 %

Open this example in the calculator and change any input.

Formula

\(F = \frac{1}{m+1} + \frac{1}{2N} + \frac{\sqrt{m-1}}{6N^2}, \quad h_f = F\,\frac{10.67\,L\,Q^{1.852}}{C^{1.852}d^{4.87}}\)

Variables

Symbol Meaning SI unit
\(L\) Lateral length m
\(s\) Outlet (emitter) spacing m
\(q\) Flow per outlet (litres per hour) -
\(d\) Lateral inside diameter m
\(C\) Hazen–Williams coefficient -
\(h\) Operating pressure head at the inlet m
\(N\) Number of outlets -
\(Q\) Inlet flow m³/s
\(F\) Christiansen factor -
\(h_f\) Friction loss along the lateral m
\(h_f/h\) Loss as a share of the operating head -

Method and standards

Christiansen factor.

Where it is used

  • Drip and sprinkler lateral design.
  • Checking pressure variation along laterals.

Common mistakes

  • Using the full-flow loss for a lateral.
  • Ignoring slope along the lateral.

Assumptions and limits

  • Equal outlets, equal spacing, level lateral, first outlet one spacing from the inlet.

Questions and answers

What is the Christiansen factor for many outlets?

About 0.35 with the Hazen–Williams exponent 1.852.

How long can a 16 mm drip lateral be?

Until friction reaches about 20 % of operating head: the defaults lose about 1.4 m of 10 m over 100 m.

What do the defaults represent?

An illustrative 100 m, 16 mm (13.8 mm bore) lateral with 2 L/h emitters every 0.6 m at 10 m head.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Christiansen, Irrigation by Sprinkling, California Agricultural Experiment Station Bulletin 670 (1942), Keller and Bliesner, Sprinkle and Trickle Irrigation (Van Nostrand Reinhold, 1990)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.