FireCADCalc

Drip Irrigation: Water per Plant and Daily Run Time

Daily water per plant and per hectare under drip irrigation and the emitter run time, from reference evapotranspiration, crop coefficient, spacing and wetted area.

Inputs

Examples: Illustrative orchard at 3 x 2 mVegetables at 1.2 x 0.4 mSugarcane, paired rows

Accepted: 0.1 to 20
Accepted: 0.1 to 1.5
Accepted: 0.1 to 20 m
Accepted: 0.1 to 20 m
Accepted: 10 to 100 %
Accepted: 50 to 100 %
Accepted: 1 to 50
Accepted: 0.5 to 50

Results

Crop water use is the reference evapotranspiration times the crop coefficient. Drip wets only part of the field, so the daily need per plant is reduced by the wetted (canopy) factor and divided by the application efficiency; 1 mm over 1 m² is 1 litre. The emitters must deliver that in the run time W/(n q). Split the run into shifts if the pump cannot supply the whole field at once.

Water per plant per day (litres)5.8500
Run time per day3.6562h
Plants per hectare13,889
Water per hectare per day81.250m³
System flow per hectare while running22.222m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative orchard at 3 x 2 m. The inputs, in the units selected above:

InputValue
Reference evapotranspiration (mm per day)6.0000 -
Crop coefficient0.90000 -
Row spacing3.0000 m
Plant spacing in the row2.0000 m
Wetted (shaded) area factor60.000 %
Application efficiency90.000 %
Emitters per plant4.0000 -
Emitter flow (litres per hour)4.0000 -

Applying the formula below gives:

ResultValue
Water per plant per day (litres)21.600
Run time per day1.3500 h
Plants per hectare1,666.7
Water per hectare per day36.000 m³
System flow per hectare while running26.667 m³/h

Open this example in the calculator and change any input.

Formula

\(W_p = \frac{ET_0 K_c P_w S_r S_p}{\eta}, \quad t = \frac{W_p}{n_e q_e}\)

Variables

Symbol Meaning SI unit
\(ET_0\) Reference evapotranspiration (mm per day) -
\(K_c\) Crop coefficient -
\(S_r\) Row spacing m
\(S_p\) Plant spacing in the row m
\(P_w\) Wetted (shaded) area factor -
\(\eta\) Application efficiency -
\(n_e\) Emitters per plant -
\(q_e\) Emitter flow (litres per hour) -
\(W_p\) Water per plant per day (litres) -
\(t\) Run time per day s
\(N\) Plants per hectare -
\(W_{ha}\) Water per hectare per day m³
\(Q_{ha}\) System flow per hectare while running m³/s

Method and standards

Drip design.

Where it is used

  • Orchards, vegetables, sugarcane and plantations.
  • Daily irrigation scheduling.

Common mistakes

  • Ignoring the wetted area factor.
  • Using pan evaporation as ET₀ without a pan coefficient.

Assumptions and limits

  • Daily average conditions; no rainfall.

Questions and answers

How much water does a mango tree at 3 × 2 m need?

About 22 litres a day at 6 mm/day ET₀, K_c 0.9 and 60 % wetted area.

How long should drip run?

Water per plant divided by the emitter output: 21.6 L with four 4 L/h emitters is about 1.35 h.

What do the defaults represent?

An illustrative orchard at 3 m × 2 m with ET₀ 6 mm/day, K_c 0.9, 60 % wetted area, 90 % efficiency and four 4 L/h emitters per plant.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Allen, Pereira, Raes and Smith, Crop Evapotranspiration, FAO Irrigation and Drainage Paper 56 (FAO, 1998), Keller and Bliesner, Sprinkle and Trickle Irrigation (Van Nostrand Reinhold, 1990)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.