Worked example
Example: Illustrative orchard at 3 x 2 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reference evapotranspiration (mm per day) | 6.0000 - |
| Crop coefficient | 0.90000 - |
| Row spacing | 3.0000 m |
| Plant spacing in the row | 2.0000 m |
| Wetted (shaded) area factor | 60.000 % |
| Application efficiency | 90.000 % |
| Emitters per plant | 4.0000 - |
| Emitter flow (litres per hour) | 4.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water per plant per day (litres) | 21.600 |
| Run time per day | 1.3500 h |
| Plants per hectare | 1,666.7 |
| Water per hectare per day | 36.000 m³ |
| System flow per hectare while running | 26.667 m³/h |
Open this example in the calculator and change any input.
Formula
\(W_p = \frac{ET_0 K_c P_w S_r S_p}{\eta}, \quad t = \frac{W_p}{n_e q_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(ET_0\) | Reference evapotranspiration (mm per day) | - |
| \(K_c\) | Crop coefficient | - |
| \(S_r\) | Row spacing | m |
| \(S_p\) | Plant spacing in the row | m |
| \(P_w\) | Wetted (shaded) area factor | - |
| \(\eta\) | Application efficiency | - |
| \(n_e\) | Emitters per plant | - |
| \(q_e\) | Emitter flow (litres per hour) | - |
| \(W_p\) | Water per plant per day (litres) | - |
| \(t\) | Run time per day | s |
| \(N\) | Plants per hectare | - |
| \(W_{ha}\) | Water per hectare per day | m³ |
| \(Q_{ha}\) | System flow per hectare while running | m³/s |
Method and standards
Drip design.
Where it is used
- Orchards, vegetables, sugarcane and plantations.
- Daily irrigation scheduling.
Common mistakes
- Ignoring the wetted area factor.
- Using pan evaporation as ET₀ without a pan coefficient.
Assumptions and limits
- Daily average conditions; no rainfall.
Questions and answers
How much water does a mango tree at 3 × 2 m need?
About 22 litres a day at 6 mm/day ET₀, K_c 0.9 and 60 % wetted area.
How long should drip run?
Water per plant divided by the emitter output: 21.6 L with four 4 L/h emitters is about 1.35 h.
What do the defaults represent?
An illustrative orchard at 3 m × 2 m with ET₀ 6 mm/day, K_c 0.9, 60 % wetted area, 90 % efficiency and four 4 L/h emitters per plant.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Allen, Pereira, Raes and Smith, Crop Evapotranspiration, FAO Irrigation and Drainage Paper 56 (FAO, 1998), Keller and Bliesner, Sprinkle and Trickle Irrigation (Van Nostrand Reinhold, 1990)