FireCADCalc

Weir Seepage: Bligh and Lane Creep Length Check

Creep length under a weir or barrage on permeable soil by Bligh's theory and Lane's weighted creep, against the length the soil's creep coefficients need.

Inputs

Examples: Illustrative weir on fine sandShort floor, unsafeGravel foundation

Accepted: 0.1 to 50 m
Accepted: 0 to 1,000 m
Accepted: 0 to 500 m
Accepted: 3 to 25
Accepted: 1.5 to 10

Results

Bligh treated seepage as creeping along the contact of floor and cut-offs, needing a length L = C·H with C from about 5 (gravel) to 18 (fine silt). Lane found horizontal paths only a third as effective as vertical ones and proposed a weighted creep L_w = L_h/3 + L_v ≥ C_w·H. Both are preliminary checks; Khosla's method of independent variables (with the exit gradient) is used for final design of floors on permeable foundations.

Bligh creep length26.000m
Bligh factor (≥ 1 safe)1.7333
Lane weighted creep length12.667m
Lane factor (≥ 1 safe)1.4074
Mean hydraulic gradient0.11538

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative weir on fine sand. The inputs, in the units selected above:

InputValue
Head across the structure4.0000 m
Horizontal creep length (floor)45.000 m
Vertical creep length (both faces of all cut-offs)14.000 m
Bligh coefficient12.000 -
Lane weighted creep ratio7.0000 -

Applying the formula below gives:

ResultValue
Bligh creep length59.000 m
Bligh factor (≥ 1 safe)1.2292
Lane weighted creep length29.000 m
Lane factor (≥ 1 safe)1.0357
Mean hydraulic gradient0.067797

Open this example in the calculator and change any input.

Formula

\(L_B = L_h + L_v \ge C_B H, \quad L_W = \frac{L_h}3 + L_v \ge C_W H\)

Variables

Symbol Meaning SI unit
\(H\) Head across the structure m
\(L_h\) Horizontal creep length (floor) m
\(L_v\) Vertical creep length (both faces of all cut-offs) m
\(C_B\) Bligh coefficient -
\(C_W\) Lane weighted creep ratio -
\(L_B\) Bligh creep length m
\(L_B/(C_BH)\) Bligh factor (≥ 1 safe) -
\(L_W\) Lane weighted creep length m
\(L_W/(C_WH)\) Lane factor (≥ 1 safe) -
\(H/L_B\) Mean hydraulic gradient -

Method and standards

Creep length.

Where it is used

  • Weir and barrage preliminary design.
  • Civil engineering examinations.

Common mistakes

  • Counting one face of a cut-off.
  • Using Bligh's coefficients in Lane's check.

Assumptions and limits

  • Homogeneous foundation.

References

  • Classical irrigation engineering relations (duty and delta, Bligh and Lane creep, Khosla exit gradient)

Questions and answers

Is a 45 m floor with 14 m of vertical creep safe for 4 m head on fine sand?

Bligh needs 48 m and gives 59 m (factor 1.23); Lane needs 28 m and gives 29 m (factor 1.04).

Why does Lane weight horizontal creep by a third?

Water finds horizontal paths along a floor easier than vertical ones around cut-offs.

What do the defaults represent?

An illustrative weir with 4 m head, 45 m floor and 14 m of vertical creep, on fine sand (Bligh 12, Lane 7).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.