FireCADCalc

Plate Load Test: Settlement of a Footing (Terzaghi–Peck)

Settlement of a footing on sand from a plate load test by the Terzaghi–Peck relation, or on clay in proportion to width, with the plate and footing widths.

Inputs

Examples: Sand, 2 m footingClay, 1.5 m footingSand, 600 mm plate, 3 m footing

Results

Terzaghi–Peck uses widths in metres with the 0.3 m term; the plate test sees only shallow soil, so check deeper layers separately.

Footing settlement30.000mm
Ratio5.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Sand, 2 m footing. The inputs, in the units selected above:

InputValue
Plate settlement at the design pressure8.0000 mm
Plate width300.00 mm
Footing width2.0000 m
SoilSand (Terzaghi–Peck)

Applying the formula below gives:

ResultValue
Footing settlement24.197 mm
Ratio3.0246

Open this example in the calculator and change any input.

Formula

\(S_f = S_p\left[\frac{B_f(B_p + 0.3)}{B_p(B_f + 0.3)}\right]^2 \ \text{(sand)}, \quad S_f = S_p\frac{B_f}{B_p} \ \text{(clay)}\)

Variables

Symbol Meaning SI unit
\(S_p\) Plate settlement at the design pressure m
\(B_p\) Plate width m
\(B_f\) Footing width m
\(\text{soil}\) Soil -
\(S_f\) Footing settlement m
\(S_f/S_p\) Ratio -

Method and standards

Empirical relation, widths in metres.

Where it is used

  • Interpreting plate load tests.
  • Foundation design checks.

Common mistakes

  • Widths in mm in the formula.
  • Ignoring the water table.

Assumptions and limits

  • Same pressure on plate and footing.
  • For sand the ratio tends to [(B_p + 0.3)/B_p]² for a very wide footing (4 for a 0.3 m plate); a footing narrower than the plate gives a ratio below 1 and gets a warning.

References

  • Terzaghi and Peck (1948) plate-to-footing settlement relation for sand; linear in width for clay

Questions and answers

8 mm under a 300 mm plate, 2 m footing on sand?

24.2 mm.

Why not just scale by width?

In sand stiffness grows with confinement, so settlement grows more slowly.

Limits?

Shallow test; a soft layer below the plate's zone is missed.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.