Worked example
Example: Sand, 2 m footing. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plate settlement at the design pressure | 8.0000 mm |
| Plate width | 300.00 mm |
| Footing width | 2.0000 m |
| Soil | Sand (Terzaghi–Peck) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Footing settlement | 24.197 mm |
| Ratio | 3.0246 |
Open this example in the calculator and change any input.
Formula
\(S_f = S_p\left[\frac{B_f(B_p + 0.3)}{B_p(B_f + 0.3)}\right]^2 \ \text{(sand)}, \quad S_f = S_p\frac{B_f}{B_p} \ \text{(clay)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_p\) | Plate settlement at the design pressure | m |
| \(B_p\) | Plate width | m |
| \(B_f\) | Footing width | m |
| \(\text{soil}\) | Soil | - |
| \(S_f\) | Footing settlement | m |
| \(S_f/S_p\) | Ratio | - |
Method and standards
Empirical relation, widths in metres.
Where it is used
- Interpreting plate load tests.
- Foundation design checks.
Common mistakes
- Widths in mm in the formula.
- Ignoring the water table.
Assumptions and limits
- Same pressure on plate and footing.
- For sand the ratio tends to [(B_p + 0.3)/B_p]² for a very wide footing (4 for a 0.3 m plate); a footing narrower than the plate gives a ratio below 1 and gets a warning.
References
- Terzaghi and Peck (1948) plate-to-footing settlement relation for sand; linear in width for clay
Questions and answers
8 mm under a 300 mm plate, 2 m footing on sand?
24.2 mm.
Why not just scale by width?
In sand stiffness grows with confinement, so settlement grows more slowly.
Limits?
Shallow test; a soft layer below the plate's zone is missed.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.