Worked example
Example: 85 m2, 3/4 in, 16 ft, 2 passes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat transfer area needed | 85.000 m² |
| Tube outside diameter | 19.050 mm |
| Effective tube length | 4.8800 m |
| Tube passes | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Tubes for the area (exact) | 291.04 |
| Tubes, rounded up to a multiple of the passes | 292.00 |
| Tubes per pass | 146.00 |
| Area provided | 85.280 m² |
Open this example in the calculator and change any input.
Formula
\(N = \frac{A}{\pi d_o L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Heat transfer area needed | m² |
| \(d_o\) | Tube outside diameter | m |
| \(L\) | Effective tube length | m |
| \(n_p\) | Tube passes | - |
| \(N_0\) | Tubes for the area (exact) | - |
| \(N\) | Tubes, rounded up to a multiple of the passes | - |
| \(N/n_p\) | Tubes per pass | - |
| \(A_{act}\) | Area provided | m² |
Method and standards
Geometry.
Where it is used
- Exchanger sizing and checking.
- Retubing.
Common mistakes
- Inside diameter with outside-based U.
- Tube sheet length included.
Assumptions and limits
- Straight tubes.
References
- A = N π d_o L
Questions and answers
85 m² with ¾-inch tubes 16 ft long, two passes?
291.0 tubes: 292 rounded to two passes.
Why outside diameter?
Areas are usually quoted on the outside of the tubes.
Effective length?
Length between tube sheets, less the tube sheet thickness.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.