FireCADCalc

Tube Bundle Diameter from Tube Count and Pitch

Diameter of a circular tube bundle for a number of tubes at a triangular or square pitch, with clearance to the shell, and how many tubes fit in a given shell.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Ganapathy Q8.50: 500 tubes at 3 in., triangular (book 70.5 in.)Same, square (book 75.7 in.)Exchanger 300 tubes 25 mm at 31.75 mm, 15 mm clearance

Results

Area-based estimate (Ganapathy): actual counts depend on pass partitions, tie rods and the outer tube limit; check with a tube-sheet layout.

Bundle diameter1,922.6mm
Diameter with clearance1,922.6mm
Tubes that fit in the given shell438.00

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy Q8.50: 500 tubes at 3 in., triangular (book 70.5 in.). The inputs, in the units selected above:

InputValue
Number of tubes500.00 -
Tube pitch76.200 mm
LayoutTriangular pitch
Clearance added to the diameter0 mm
Available shell inside diameter (for tube count)1,800.0 mm

Applying the formula below gives:

ResultValue
Bundle diameter1,789.2 mm
Diameter with clearance1,789.2 mm
Tubes that fit in the given shell506.00

Open this example in the calculator and change any input.

Formula

\(D_b = 1.05\,p_t\sqrt N\ \text{(triangular)}, \quad D_b = 1.128\,p_t\sqrt N\ \text{(square)}\)

Variables

Symbol Meaning SI unit
\(N\) Number of tubes -
\(p_t\) Tube pitch m
\(\text{layout}\) Layout -
\(c\) Clearance added to the diameter m
\(D_s\) Available shell inside diameter (for tube count) m
\(D_b\) Bundle diameter m
\(D_b + c\) Diameter with clearance m
\(N_{max}\) Tubes that fit in the given shell -

Method and standards

Area-equivalence.

Where it is used

  • Fire-tube boiler and shell-and-tube exchanger layout.
  • Retubing checks.

Common mistakes

  • Forgetting pass-partition lanes.
  • Pitch less than 1.25 d_o.

Assumptions and limits

  • Uniform pitch over the whole circle.
  • The area-equivalent diameter is that of the tube field to the pitch-cell boundary, not the outer tube limit; the tube outside diameter is not an input, so allow for it in the shell clearance and check with a tube layout.

References

  • Ganapathy
  • Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
  • Q8.50 (bundle diameter: D = 1.05p√N triangular, 1.128p√N square)

Questions and answers

Where do 1.05 and 1.128 come from?

Each tube occupies 0.866p² on a triangular pitch and p² on a square one; equating N times that to the circle area gives D.

What does Ganapathy's example give?

500 tubes of 2 in. at 3 in. pitch: 70.5 in. triangular, 75.7 in. square.

Which pitch is better?

Triangular packs about 15 % more tubes; square allows mechanical cleaning lanes.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.