Worked example
Example: Ganapathy Q8.50: 500 tubes at 3 in., triangular (book 70.5 in.). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of tubes | 500.00 - |
| Tube pitch | 76.200 mm |
| Layout | Triangular pitch |
| Clearance added to the diameter | 0 mm |
| Available shell inside diameter (for tube count) | 1,800.0 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bundle diameter | 1,789.2 mm |
| Diameter with clearance | 1,789.2 mm |
| Tubes that fit in the given shell | 506.00 |
Open this example in the calculator and change any input.
Formula
\(D_b = 1.05\,p_t\sqrt N\ \text{(triangular)}, \quad D_b = 1.128\,p_t\sqrt N\ \text{(square)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Number of tubes | - |
| \(p_t\) | Tube pitch | m |
| \(\text{layout}\) | Layout | - |
| \(c\) | Clearance added to the diameter | m |
| \(D_s\) | Available shell inside diameter (for tube count) | m |
| \(D_b\) | Bundle diameter | m |
| \(D_b + c\) | Diameter with clearance | m |
| \(N_{max}\) | Tubes that fit in the given shell | - |
Method and standards
Area-equivalence.
Where it is used
- Fire-tube boiler and shell-and-tube exchanger layout.
- Retubing checks.
Common mistakes
- Forgetting pass-partition lanes.
- Pitch less than 1.25 d_o.
Assumptions and limits
- Uniform pitch over the whole circle.
- The area-equivalent diameter is that of the tube field to the pitch-cell boundary, not the outer tube limit; the tube outside diameter is not an input, so allow for it in the shell clearance and check with a tube layout.
References
- Ganapathy
- Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
- Q8.50 (bundle diameter: D = 1.05p√N triangular, 1.128p√N square)
Questions and answers
Where do 1.05 and 1.128 come from?
Each tube occupies 0.866p² on a triangular pitch and p² on a square one; equating N times that to the circle area gives D.
What does Ganapathy's example give?
500 tubes of 2 in. at 3 in. pitch: 70.5 in. triangular, 75.7 in. square.
Which pitch is better?
Triangular packs about 15 % more tubes; square allows mechanical cleaning lanes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.