Batch Cooling Time with a Jacket or Coil

Time to cool a stirred batch from one temperature to another with coolant of constant inlet temperature through a jacket or coil, from U, area and coolant flow.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: 8 t from 120 to 50 °CSmall batch, low flow

Results

Well-mixed batch, constant U and coolant flow; agitator heat and reaction heat are ignored.

e^(UA/wc)1.7756
Cooling time2.6769h
Coolant outlet at the start53.394°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 t from 120 to 50 °C. The inputs, in the units selected above:

InputValue
Batch mass8,000.0 kg
Batch specific heat3.2000 kJ/(kg·K)
Batch start temperature120.00 °C
Batch end temperature50.000 °C
Coolant inlet temperature30.000 °C
Coolant flow14,400 kg/h
Coolant specific heat4.1800 kJ/(kg·K)
Overall coefficient400.00 W/(m²·K)
Heat transfer area15.000 m²

Applying the formula below gives:

ResultValue
e^(UA/wc)1.4317
Cooling time2.1215 h
Coolant outlet at the start57.137 °C

Open this example in the calculator and change any input.

Formula

\(t = \frac{M C_p}{w c}\cdot\frac{K}{K - 1}\ln\frac{T_1 - t_1}{T_2 - t_1}, \quad K = e^{UA/(wc)}\)

Variables

Symbol Meaning SI unit
\(M\) Batch mass kg
\(C_p\) Batch specific heat J/(kg·K)
\(T_1\) Batch start temperature K
\(T_2\) Batch end temperature K
\(t_1\) Coolant inlet temperature K
\(w\) Coolant flow kg/s
\(c\) Coolant specific heat J/(kg·K)
\(U\) Overall coefficient W/(m²·K)
\(A\) Heat transfer area m²
\(K\) e^(UA/wc) -
\(t\) Cooling time s
\(t_{2,0}\) Coolant outlet at the start K

Method and standards

Batch energy balance.

Where it is used

  • Batch reactors, crystallisers and cooling tanks.
  • Cycle time planning.

Common mistakes

  • Using LMTD with fixed temperatures.
  • Ignoring reaction heat.

Assumptions and limits

  • Constant U, coolant flow and inlet temperature.

References

  • Energy balance on a stirred batch with coolant leaving at t₂ = T − (T − t₁)/K
  • K = e^(UA/wc) (Kern, Process Heat Transfer, batch cooling)

Questions and answers

8 t from 120 to 50 °C with 4 kg/s of water at 30 °C, UA 6000 W/K?

About 2.1 h.

Why does it slow down?

The driving difference shrinks as the batch nears the water temperature.

Heating with a liquid?

The same form applies with the signs reversed.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.