Worked example
Example: 8 t from 120 to 50 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Batch mass | 8,000.0 kg |
| Batch specific heat | 3.2000 kJ/(kg·K) |
| Batch start temperature | 120.00 °C |
| Batch end temperature | 50.000 °C |
| Coolant inlet temperature | 30.000 °C |
| Coolant flow | 14,400 kg/h |
| Coolant specific heat | 4.1800 kJ/(kg·K) |
| Overall coefficient | 400.00 W/(m²·K) |
| Heat transfer area | 15.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| e^(UA/wc) | 1.4317 |
| Cooling time | 2.1215 h |
| Coolant outlet at the start | 57.137 °C |
Open this example in the calculator and change any input.
Formula
\(t = \frac{M C_p}{w c}\cdot\frac{K}{K - 1}\ln\frac{T_1 - t_1}{T_2 - t_1}, \quad K = e^{UA/(wc)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(M\) | Batch mass | kg |
| \(C_p\) | Batch specific heat | J/(kg·K) |
| \(T_1\) | Batch start temperature | K |
| \(T_2\) | Batch end temperature | K |
| \(t_1\) | Coolant inlet temperature | K |
| \(w\) | Coolant flow | kg/s |
| \(c\) | Coolant specific heat | J/(kg·K) |
| \(U\) | Overall coefficient | W/(m²·K) |
| \(A\) | Heat transfer area | m² |
| \(K\) | e^(UA/wc) | - |
| \(t\) | Cooling time | s |
| \(t_{2,0}\) | Coolant outlet at the start | K |
Method and standards
Batch energy balance.
Where it is used
- Batch reactors, crystallisers and cooling tanks.
- Cycle time planning.
Common mistakes
- Using LMTD with fixed temperatures.
- Ignoring reaction heat.
Assumptions and limits
- Constant U, coolant flow and inlet temperature.
References
- Energy balance on a stirred batch with coolant leaving at t₂ = T − (T − t₁)/K
- K = e^(UA/wc) (Kern, Process Heat Transfer, batch cooling)
Questions and answers
8 t from 120 to 50 °C with 4 kg/s of water at 30 °C, UA 6000 W/K?
About 2.1 h.
Why does it slow down?
The driving difference shrinks as the batch nears the water temperature.
Heating with a liquid?
The same form applies with the signs reversed.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.