FireCADCalc

Rotary Kiln Residence Time and Degree of Filling

Material residence time in a rotary kiln by the US Bureau of Mines formula from length, diameter, slope, speed and repose angle, with hold-up and filling.

Inputs

Examples: Duda's example: 328 ft x 10 ft, 2.66 deg, 1.3 rpmPreheater kiln 4.2 x 64 m, 3.5 %, 3.5 rpmLime kiln with constriction factor 1.2

Results

The Bureau of Mines formula treats the kiln as uniform; real material moves fastest in the calcining zone and slowest in the burning zone. Hold-up uses the feed rate throughout (no allowance for mass loss on calcination).

Residence time115.53min
Material hold-up48.137t
Kiln internal volume817.13m³
Degree of filling3.9273%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Duda's example: 328 ft x 10 ft, 2.66 deg, 1.3 rpm. The inputs, in the units selected above:

InputValue
Kiln length99.974 m
Kiln inside diameter3.0480 m
Kiln slope2.6600 °
Kiln speed1.3000 rpm
Angle of repose of the material40.000 °
Constriction factor (1 for a straight kiln)1.0000 -
Material feed rate60.000 t/h
Bulk density of the bed1,400.0 kg/m³

Applying the formula below gives:

ResultValue
Residence time106.18 min
Material hold-up106.18 t
Kiln internal volume729.47 m³
Degree of filling10.397 %

Open this example in the calculator and change any input.

Formula

\(t = \frac{1.77\,L\sqrt{\Theta}\,F}{p\,d\,n}\ \ (\text{min; }L, d\ \text{ft},\ p, \Theta\ \text{degrees},\ n\ \text{rpm}), \quad f = \frac{\dot m t}{\rho_b V_k}\)

Variables

Symbol Meaning SI unit
\(L\) Kiln length m
\(d\) Kiln inside diameter m
\(p\) Kiln slope rad
\(n\) Kiln speed 1/s
\(\Theta\) Angle of repose of the material rad
\(F\) Constriction factor (1 for a straight kiln) -
\(\dot m\) Material feed rate kg/s
\(\rho_b\) Bulk density of the bed kg/m³
\(t\) Residence time s
\(M\) Material hold-up kg
\(V_k\) Kiln internal volume m³
\(f\) Degree of filling -

Method and standards

US Bureau of Mines formula.

Where it is used

  • Kiln and dryer design.
  • Setting kiln speed for a new production rate.

Common mistakes

  • Entering slope in percent as degrees.
  • Using the shell diameter.

Assumptions and limits

  • Free-flowing bed, no dams.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • secs. 19.1.1 and 19.1.5 (US Bureau of Mines formula)
  • Boateng
  • Rotary Kilns: Transport Phenomena and Transport Processes (Elsevier, 2008)
  • ch. 3 (bed residence time)

Questions and answers

How do slope and speed change residence time?

Inversely: doubling either halves the time, which is why operators use kiln speed to control the feed's passage.

What filling is normal?

Duda gives 5–17 % of the kiln cross-section; modern preheater kilns run near the low end.

What do the defaults represent?

Duda's example: a 328 ft × 10 ft kiln at 2°40′ slope and 1.3 rpm with a 40° angle of repose (106 min), fed 60 t/h of 1.4 t/m³ material.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.