Worked example
Example: Duda's example: 328 ft x 10 ft, 2.66 deg, 1.3 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Kiln length | 99.974 m |
| Kiln inside diameter | 3.0480 m |
| Kiln slope | 2.6600 ° |
| Kiln speed | 1.3000 rpm |
| Angle of repose of the material | 40.000 ° |
| Constriction factor (1 for a straight kiln) | 1.0000 - |
| Material feed rate | 60.000 t/h |
| Bulk density of the bed | 1,400.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Residence time | 106.18 min |
| Material hold-up | 106.18 t |
| Kiln internal volume | 729.47 m³ |
| Degree of filling | 10.397 % |
Open this example in the calculator and change any input.
Formula
\(t = \frac{1.77\,L\sqrt{\Theta}\,F}{p\,d\,n}\ \ (\text{min; }L, d\ \text{ft},\ p, \Theta\ \text{degrees},\ n\ \text{rpm}), \quad f = \frac{\dot m t}{\rho_b V_k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Kiln length | m |
| \(d\) | Kiln inside diameter | m |
| \(p\) | Kiln slope | rad |
| \(n\) | Kiln speed | 1/s |
| \(\Theta\) | Angle of repose of the material | rad |
| \(F\) | Constriction factor (1 for a straight kiln) | - |
| \(\dot m\) | Material feed rate | kg/s |
| \(\rho_b\) | Bulk density of the bed | kg/m³ |
| \(t\) | Residence time | s |
| \(M\) | Material hold-up | kg |
| \(V_k\) | Kiln internal volume | m³ |
| \(f\) | Degree of filling | - |
Method and standards
US Bureau of Mines formula.
Where it is used
- Kiln and dryer design.
- Setting kiln speed for a new production rate.
Common mistakes
- Entering slope in percent as degrees.
- Using the shell diameter.
Assumptions and limits
- Free-flowing bed, no dams.
References
- Duda
- Cement Data Book
- Vol. 1
- 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
- secs. 19.1.1 and 19.1.5 (US Bureau of Mines formula)
- Boateng
- Rotary Kilns: Transport Phenomena and Transport Processes (Elsevier, 2008)
- ch. 3 (bed residence time)
Questions and answers
How do slope and speed change residence time?
Inversely: doubling either halves the time, which is why operators use kiln speed to control the feed's passage.
What filling is normal?
Duda gives 5–17 % of the kiln cross-section; modern preheater kilns run near the low end.
What do the defaults represent?
Duda's example: a 328 ft × 10 ft kiln at 2°40′ slope and 1.3 rpm with a 40° angle of repose (106 min), fed 60 t/h of 1.4 t/m³ material.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.