Worked example
Example: 12 m³ fluid, 18 t steel, 30 → 280 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid volume in the system | 12.000 m³ |
| Mean fluid density | 850.00 kg/m³ |
| Mean fluid specific heat | 2.3000 kJ/(kg·K) |
| Mass of steel heated (heater, pipes, vessels) | 18.000 t |
| Steel specific heat | 0.50000 kJ/(kg·K) |
| Start temperature | 30.000 °C |
| Operating temperature | 280.00 °C |
| Heater output | 1,200.0 kW |
| Heat loss at operating temperature | 40.000 kW |
| Maximum allowed heating rate | 50.000 °C/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat stored | 2,254.2 kWh |
| Time limited by heater output | 1.9105 h |
| Time limited by heating rate | 5.0000 h |
| Heat-up time | 5.0000 h |
Open this example in the calculator and change any input.
Formula
\(C = V_f\rho c_p + m_sc_s, \quad t_Q = \frac{C(T_2 - T_1)}{Q_l}\ln\frac{Q_h}{Q_h - Q_l}, \quad t_r = \frac{T_2 - T_1}{r_{max}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Fluid volume in the system | m³ |
| \(\rho\) | Mean fluid density | kg/m³ |
| \(c_p\) | Mean fluid specific heat | J/(kg·K) |
| \(m_s\) | Mass of steel heated (heater, pipes, vessels) | kg |
| \(c_s\) | Steel specific heat | J/(kg·K) |
| \(T_1\) | Start temperature | K |
| \(T_2\) | Operating temperature | K |
| \(Q_h\) | Heater output | W |
| \(Q_l\) | Heat loss at operating temperature | W |
| \(r_{max}\) | Maximum allowed heating rate | K/s |
| \(E\) | Heat stored | J |
| \(t_Q\) | Time limited by heater output | s |
| \(t_r\) | Time limited by heating rate | s |
| \(t\) | Heat-up time | s |
Method and standards
Lumped heat balance.
Where it is used
- Commissioning and restart planning.
- Heater sizing for quick start-up.
Common mistakes
- Forgetting the steel mass.
- Exceeding the fluid maker's heating rate.
Assumptions and limits
- Uniform temperature; constant heater output.
- The heat loss is zero at the start temperature and rises in proportion to the temperature rise, reaching Q_l at the operating temperature. Starting from a warm system (above ambient) the losses are underestimated.
References
- Lumped energy balance with loss proportional to temperature rise (definitions)
Questions and answers
Why hold at around 110 °C?
To boil off water in a new or opened system slowly; water flashing at higher temperature can surge the expansion tank.
Which limit usually governs?
The allowed heating rate, unless the heater is small for the system.
What do the defaults give?
12 m³ of fluid and 18 t of steel from 30 to 280 °C: about 2,250 kWh stored; the 50 K/h limit sets 5 h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.