Worked example
Example: 1 MW, 7,000 h, fuel 500/GJ. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Process heat demand | 1,000.0 kW |
| Operating hours per year | 7,000.0 h |
| Fuel cost (currency per GJ) | 500.00 - |
| Electricity cost (currency per kWh) | 8.0000 - |
| Thermic fluid heater efficiency | 85.000 % |
| Thermic fluid pump power | 15.000 kW |
| Steam boiler efficiency | 82.000 % |
| Steam distribution, trap, flash and condensate losses | 15.000 % |
| Water treatment and blowdown cost per GJ of steam (currency) | 15.000 - |
| Feed pump and other steam-side power | 8.0000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Annual cost, thermic fluid | 1.5664e+07 |
| Annual cost, steam | 1.8970e+07 |
| Saving with thermic fluid | 3,306,651 |
| Saving as share of steam cost | 17.431 % |
Open this example in the calculator and change any input.
Formula
\(C_{tf} = \frac{Qt_a}{\eta_{tf}}c_f + P_{tf}t_ac_e, \quad C_{st} = \frac{Qt_a}{\eta_b(1 - f_s)}c_f + \frac{Qt_a}{1 - f_s}c_w + P_{fw}t_ac_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Process heat demand | W |
| \(t_a\) | Operating hours per year | s |
| \(c_f\) | Fuel cost (currency per GJ) | - |
| \(c_e\) | Electricity cost (currency per kWh) | - |
| \(\eta_{tf}\) | Thermic fluid heater efficiency | - |
| \(P_{tf}\) | Thermic fluid pump power | W |
| \(\eta_b\) | Steam boiler efficiency | - |
| \(f_s\) | Steam distribution, trap, flash and condensate losses | - |
| \(c_w\) | Water treatment and blowdown cost per GJ of steam (currency) | - |
| \(P_{fw}\) | Feed pump and other steam-side power | W |
| \(C_{tf}\) | Annual cost, thermic fluid | - |
| \(C_{st}\) | Annual cost, steam | - |
| \(\Delta C\) | Saving with thermic fluid | - |
| \(\Delta C/C_{st}\) | Saving as share of steam cost | - |
Method and standards
Annual cost definitions.
Where it is used
- Choosing a heating medium for a new process.
- Converting steam users to thermic fluid.
Common mistakes
- Ignoring steam-side losses.
- Comparing at different delivered temperatures.
Assumptions and limits
- Same delivered heat.
- The steam side has a distribution, trap, flash and condensate loss share; the thermic fluid loop has no separate distribution loss input, although its pipes also lose heat. Include that loss in the thermic fluid heater efficiency, or the comparison favours thermic fluid.
- The fuel cost per GJ and both efficiencies must be on the same calorific basis (GCV or NCV).
References
- Energy balance and annual cost definitions
Questions and answers
Where does thermic fluid save?
No flash, trap, condensate or blowdown losses and no water treatment; the fluid returns hot in a closed loop.
When is steam better?
For large loads at moderate temperature, direct injection, or where waste steam is already available.
What do the defaults give?
1 MW for 7,000 h at fuel 500 per GJ: thermic fluid about 156.6 lakh (1.57 crore) a year, steam about 189.7 lakh (1.90 crore), a saving of about 17 %.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.