FireCADCalc

Part Load: Sliding Pressure versus Throttle Control

HP turbine inlet temperature and isentropic drop at part load with throttle control and with sliding pressure, and the feed pump work saved.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Illustrative 160 bar unit at 60 % loadSubcritical 130 bar at 40 %Industrial 65 bar at 70 %

Accepted: 20 to 300 bar
Accepted: 300 to 620 °C
Accepted: 2 to 100 bar
Accepted: 20 to 100 %
Accepted: 50 to 95 %

Results

Throttling keeps boiler pressure at p₀ and drops it in the control valves at constant enthalpy, cooling the steam slightly and wasting availability; sliding pressure lets boiler pressure fall with load (turbine stage pressures scale with flow) and keeps full temperature. HP exhaust pressure is taken proportional to flow in both. Feed pump work saved ≈ vΔp/η with feedwater at about 180 °C. Throttle response is faster, so many units use modified sliding pressure.

Turbine inlet temperature, throttled499.84°C
HP isentropic drop, throttle428.57kJ/kg
HP isentropic drop, sliding451.80kJ/kg
HP drop gain by sliding5.4217%
Feed pump work saved per kg10.896kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 160 bar unit at 60 % load. The inputs, in the units selected above:

InputValue
Rated main steam pressure160.00 bar
Main steam temperature540.00 °C
Rated HP exhaust pressure40.000 bar
Load (flow) fraction60.000 %
Feed pump efficiency80.000 %

Applying the formula below gives:

ResultValue
Turbine inlet temperature, throttled512.61 °C
HP isentropic drop, throttle402.10 kJ/kg
HP isentropic drop, sliding420.79 kJ/kg
HP drop gain by sliding4.6476 %
Feed pump work saved per kg8.9219 kJ/kg

Open this example in the calculator and change any input.

Formula

\(p_1 = Lp_0, \quad \Delta h_s = h(p_1, \cdot) - h(Lp_x, s_1), \quad \Delta w_{fp} = \frac{v(p_0 - p_1)}{\eta_{fp}}\)

Variables

Symbol Meaning SI unit
\(p_0\) Rated main steam pressure Pa
\(T_0\) Main steam temperature K
\(p_x\) Rated HP exhaust pressure Pa
\(L\) Load (flow) fraction -
\(\eta_{fp}\) Feed pump efficiency -
\(T_{1,thr}\) Turbine inlet temperature, throttled K
\(\Delta h_{s,thr}\) HP isentropic drop, throttle J/kg
\(\Delta h_{s,sl}\) HP isentropic drop, sliding J/kg
\(\Delta h_{sl}/\Delta h_{thr} - 1\) HP drop gain by sliding -
\(\Delta w_{fp}\) Feed pump work saved per kg J/kg

Method and standards

Part-load control.

Where it is used

  • Unit operating mode studies.
  • Explaining part-load heat rate.

Common mistakes

  • Comparing at different exhaust pressures.
  • Ignoring boiler response limits of sliding pressure.

Assumptions and limits

  • Stage pressures proportional to flow; HP section only; IAPWS-IF97.

References

  • Part-load comparison with IAPWS-IF97 and flow-proportional stage pressures

Questions and answers

Why does sliding pressure help at part load?

Steam enters the turbine at full temperature without throttling losses, and the feed pump does less work.

Why do units still keep some throttling margin?

Fully open valves leave no stored reserve for fast load increases; modified sliding pressure keeps a small throttle margin.

What do the defaults represent?

An illustrative 160 bar/540 °C unit with 40 bar HP exhaust at 60 % load, feed pump efficiency 80 %.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Leizerovich, Steam Turbines for Modern Fossil-Fuel Power Plants (Fairmont Press, 2008), Kehlhofer, Hannemann, Stirnimann and Rukes, Combined-Cycle Gas and Steam Turbine Power Plants, 3rd ed. (PennWell, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.