Worked example
Example: Illustrative 160 bar unit at 60 % load. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rated main steam pressure | 160.00 bar |
| Main steam temperature | 540.00 °C |
| Rated HP exhaust pressure | 40.000 bar |
| Load (flow) fraction | 60.000 % |
| Feed pump efficiency | 80.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Turbine inlet temperature, throttled | 512.61 °C |
| HP isentropic drop, throttle | 402.10 kJ/kg |
| HP isentropic drop, sliding | 420.79 kJ/kg |
| HP drop gain by sliding | 4.6476 % |
| Feed pump work saved per kg | 8.9219 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(p_1 = Lp_0, \quad \Delta h_s = h(p_1, \cdot) - h(Lp_x, s_1), \quad \Delta w_{fp} = \frac{v(p_0 - p_1)}{\eta_{fp}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_0\) | Rated main steam pressure | Pa |
| \(T_0\) | Main steam temperature | K |
| \(p_x\) | Rated HP exhaust pressure | Pa |
| \(L\) | Load (flow) fraction | - |
| \(\eta_{fp}\) | Feed pump efficiency | - |
| \(T_{1,thr}\) | Turbine inlet temperature, throttled | K |
| \(\Delta h_{s,thr}\) | HP isentropic drop, throttle | J/kg |
| \(\Delta h_{s,sl}\) | HP isentropic drop, sliding | J/kg |
| \(\Delta h_{sl}/\Delta h_{thr} - 1\) | HP drop gain by sliding | - |
| \(\Delta w_{fp}\) | Feed pump work saved per kg | J/kg |
Method and standards
Part-load control.
Where it is used
- Unit operating mode studies.
- Explaining part-load heat rate.
Common mistakes
- Comparing at different exhaust pressures.
- Ignoring boiler response limits of sliding pressure.
Assumptions and limits
- Stage pressures proportional to flow; HP section only; IAPWS-IF97.
References
- Part-load comparison with IAPWS-IF97 and flow-proportional stage pressures
Questions and answers
Why does sliding pressure help at part load?
Steam enters the turbine at full temperature without throttling losses, and the feed pump does less work.
Why do units still keep some throttling margin?
Fully open valves leave no stored reserve for fast load increases; modified sliding pressure keeps a small throttle margin.
What do the defaults represent?
An illustrative 160 bar/540 °C unit with 40 bar HP exhaust at 60 % load, feed pump efficiency 80 %.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Leizerovich, Steam Turbines for Modern Fossil-Fuel Power Plants (Fairmont Press, 2008), Kehlhofer, Hannemann, Stirnimann and Rukes, Combined-Cycle Gas and Steam Turbine Power Plants, 3rd ed. (PennWell, 2009)