FireCADCalc

Recuperated Gas Turbine Cycle Efficiency and Specific Work

Specific work, heat input and thermal efficiency of a simple gas turbine cycle with a recuperator of given effectiveness, compared with the same cycle unrecuperated.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative ratio 8, 1100 C, 85 % recuperatorMicroturbine ratio 4, 950 CHot day ratio 6

Accepted: -43.15 to 56.85 °C
Accepted: 1.5 to 50
Accepted: 526.85 to 1,726.8 °C
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 0.95 to 1.25 kJ/(kg·K)
Accepted: 1.25 to 1.41
Accepted: 0 to 98 %

Results

Air-standard cycle with constant c_p: the recuperator heats compressor air from T₂ towards the exhaust T₄, cutting fuel by c_p(T₅ − T₂) without changing net work (recuperator pressure losses neglected). It pays only at low pressure ratios where T₄ is well above T₂: microturbines and some marine units use r_p 4–10 with ε ≈ 0.85–0.9.

Compressor outlet temperature266.24°C
Turbine exhaust temperature615.25°C
Air to combustor after recuperator545.44°C
Net specific work229.37kJ/kg
Thermal efficiency, recuperated41.326%
Thermal efficiency without recuperator26.604%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative ratio 8, 1100 C, 85 % recuperator. The inputs, in the units selected above:

InputValue
Compressor inlet temperature15.000 °C
Overall pressure ratio8.0000 -
Turbine inlet temperature1,100.0 °C
Compressor isentropic efficiency85.000 %
Turbine isentropic efficiency88.000 %
Mean specific heat1.1000 kJ/(kg·K)
Heat capacity ratio1.3600 -
Recuperator effectiveness85.000 %

Applying the formula below gives:

ResultValue
Compressor outlet temperature263.83 °C
Turbine exhaust temperature588.49 °C
Air to combustor after recuperator539.79 °C
Net specific work288.95 kJ/kg
Thermal efficiency, recuperated46.889 %
Thermal efficiency without recuperator31.414 %

Open this example in the calculator and change any input.

Formula

\(T_5 = T_2 + \varepsilon(T_4 - T_2), \quad \eta = \frac{c_p[(T_3 - T_4) - (T_2 - T_1)]}{c_p(T_3 - T_5)}\)

Variables

Symbol Meaning SI unit
\(T_1\) Compressor inlet temperature K
\(r_p\) Overall pressure ratio -
\(T_3\) Turbine inlet temperature K
\(\eta_c\) Compressor isentropic efficiency -
\(\eta_t\) Turbine isentropic efficiency -
\(c_p\) Mean specific heat J/(kg·K)
\(\gamma\) Heat capacity ratio -
\(\varepsilon\) Recuperator effectiveness -
\(T_2\) Compressor outlet temperature K
\(T_4\) Turbine exhaust temperature K
\(T_5\) Air to combustor after recuperator K
\(w_{net}\) Net specific work J/kg
\(\eta\) Thermal efficiency, recuperated -
\(\eta_0\) Thermal efficiency without recuperator -

Method and standards

Recuperated cycle.

Where it is used

  • Microturbine and small CHP assessment.
  • Comparing cycle options.

Common mistakes

  • Recuperating at high pressure ratios.
  • Ignoring recuperator pressure drop.

Assumptions and limits

  • Constant c_p and γ; no pressure losses; same mass flow throughout.

References

  • Air-standard Brayton cycle with recuperation

Questions and answers

Why does recuperation suit low pressure ratios?

At low ratios the turbine exhaust is much hotter than compressor delivery, leaving plenty of heat to recover.

Does a recuperator change net work?

Ideally not; it reduces fuel. Real recuperators add pressure losses that cost a little work.

What do the defaults represent?

An illustrative cycle at pressure ratio 8, 15 °C inlet, 1,100 °C turbine inlet, 85/88 % efficiencies and an 85 % effective recuperator.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers, Cohen and Straznicky, Gas Turbine Theory, 6th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.